Specifications
A-6 Safety-door Switch D4NS
D4NS
Safety Door
Switches
Operation Keys
Specifications
■ Standards and EC Directives
• Conforms to the following EC Directives:
Machinery Directive
Low Voltage Directive
EN50047
EN1088
GS-ET-15
■ Approved Standards
Note: 1. Consult your OMRON representative for details.
2. Approval for CSA C22.2 No. 14 is authorized by the UL
mark.
3. Ask your OMRON representative for information on
approved models.
■ Approved Standard Ratings
TÜV (EN60947-5-1), CCC (GB14048.5)
Note: Use a 10-A fuse type gI or gG that conforms to IEC60269 as a
short-circuit protection device. This fuse is not built into the
Switch.
UL/CSA (UL508, CSA C22.2 No. 14)
A300
Q300
Type Model
D4DS-K1
D4DS-K2
D4DS-K3
D4DS-K5
Horizontal mounting
Vertical mounting
Adjustable mounting
(Horizontal)
Adjustable mounting
(Horizontal/Vertical)
Agency Standard File No.
TÜV Product
Service
EN60947-5-1 (approved
direct opening)
(See note 1.)
UL (See note.) UL508, CSA C22.2 No.14 E76675
CQC (CCC) GB14048.5 2003010305077
330
Item Utilization
category
AC-15 DC-13
Rated operating current (I
e
) 3 A 0.27 A
Rated operating voltage (U
e
) 240 V 250 V
Rated
voltage
Carry current Current Volt-amperes
Make Break Make Break
120 VAC 10 A 60 A 6 A 7,200 VA 720 VA
240 VAC 30 A 3 A
Rated
voltage
Carry current Current Volt-amperes
Make Break Make Break
125 VDC 2.5 A 0.55 A 0.55 A 69 VA 69 VA
250 VDC 0.27 A 0.27 A