Technical data

84 | Setting and monitoring the dispenser Operating manual ALX 73x | file version 02 | 03/2012
S
TARTUP
AND
OPERATION
ALX
73x
Suppressing start signals
The shape of the product or reflecting surfaces can
cause a premature start signal, which will result in in-
correct labelling. Start signals can therefore be ignored
in cases such as these, while the product is being
moved along under the dispensing edge. Function
LABEL SETUP > Product length must be set to the product
length for this purpose.
Example:
When the product [82D] reaches the product
sensor [82C], a start signal is generated and the ma-
chine dispenses a label. The recesses in the product
generate additional start signals, which could cause the
product to be labelled more than once. The product
length setting [82A] in function LABEL SETUP >
Product length causes the machine to ignore all start sig-
nals until the product has passed the dispensing head.
Label position on the product
Requirements:
Label length is set
Label stop position is set
Setting in dispensing mode:
Set the start delay (also called start offset) with the
two right keys (see Online settings on page 39).
Or:
Open LABEL SETUP > Start offset and set the start de-
lay.
The label should be flush with the front of the product:
Enter the distance between product sensor and dis-
pensing edge [83A].
The label should be applied at a distance from the front
of the product:
Add the distance [84A] to the front of the product to
the value for start delay.
[82] Labelling of products that generate multiple start signals.
A Product length
B Label
C Product sensor
D Product with recesses (arrows)
A
D
C
B
[83] The distance between the product sensor (left) and the
dispensing edge (right).
[84] The distance (A) between the label and the front of the
product.
A
A