Technical data

Operating manual ALX 73x | file version 02 | 03/2012 Dispenser parameter menu | 55
P
RODUCT
DESCRIPTION
ALX
73x
GB
Materialend warn Related to internal OD monitoring.
Settings: [Disabled, „Mat.diam < x mm“]
Setting range for x = [50…500]
Default setting: x= 80
Disabling the function:
Set x < 40.
Re-enabling the function:
Press the key.
Defines the diameter threshold for the material roll. If the (calculated) material roll di-
ameter is below the threshold value, the following warning appears:
Rewinder full Defines the maximum permissible diameter of the wound backing paper on the back-
ing paper rewinder. If the diameter is exceeded, the following message appears:
Setting range: [50…500]; default: 270 mm
ONLINE
Material low
Status num: 5064
Rewinder full