Technical data
Operating manual ALX 73x | file version 02 | 03/2012 Dispenser parameter menu | 53
P
RODUCT
DESCRIPTION
ALX
73x
GB
Slew speed Feed speed during initialisation
Setting range: [5.0…50.0] m/min; default: 1,0
Label pitch Label pitch = label length+gap
Setting range: [5,0…600,0] mm; default: 100,0 mm
Lab. stop offset Stop position of the label on the dispensing plate
Setting range: [0,0…999,9] mm; default: 20,0
Start offset Distance between product sensor and the tip of the dispensing plate. The setting af-
fects the position of the label on the product.
Setting range: [15,0…2999,9] mm; default: 15,0
Product length Start signals are suppressed while the product length is being set.
Setting range: [0.0…1999.9] mm; default: 0.0 mm
The product length function is helpful for example with products that have an
uneven surface, which would cause multiple start signals.
Multi label mode Settings: [Disabled, "x labels/start"]
• Disabled: One label is dispensed for each start signal
• "x labels/start": x labels are dispensed for each start signal; x = [2…20]
x > 3: The distance of all following labels after the 2nd label matches the value set
in LABEL SETUP > Label 2 offset.
The "Multi label mode" function only works if the start signal is sent via a standard
signal input (M12 or D-Sub 15). - It does not work if the applicator interface is used as
a signal input.
Label 2 offset Only appears, if LABEL SETUP > Multi label mode = „x labels/start“.
Defines the distance of the 2nd label and of all following labels, if x > 3 (see LABEL SET-
UP > Multi label mode). The distance is measured from the front edge of the preceding
label.
Setting range: [x…9999.9] mm; default: x, where
x = LABEL SETUP > Label pitch.
Label 3 offset Only appears, if LABEL SETUP > Multi label mode = „3 labels/start“.
Defines the distance of the third label for the function LABEL SETUP > Multi label mode (see
above). The distance is measured from the front edge of the preceding label.
Setting range: [x…9999.9] mm; default: x, where
x = LABEL SETUP > Label pitch.
Miss. label tol. Missing label tolerance
Maximum permitted number of successive labels on the label belt
Setting range: [0…10]; default: 1
Stop count. mode Settings: [Enabled, Disabled]
Enabled: Dispensing counter counts backwards, starting with the value set in LABEL
SETUP > Label stop quan. After 0 is reached, no other labels are dispensed.