Technical data
102 | Reference status messages - dispenser Operating manual ALX 73x | file version 01 | 03/2012
O
PERATING
FAULTS
ALX
73x
5147 Tandemsynch. init
Initialization of tandem synchronisation
This message can only occur in tandem
operation.
Communication between master and slave machine is not working.
Check the tandem interface cable (cable present and correctly connected?).
Check the settings on both machines.
5152 Winding direct.
The backing paper was incorrectly fastened on the rewinder core.
Fasten the backing paper on the rewinder as described in the operating manual.
Wrong machine type set (MACHINE SETUP > Dispenser type)
"RH" setting on LH machine or vice versa.
5200 Home position
The applicator has not reached its home position (upper limit stop) within the assigned
time period. This message can only occur in applicator mode.
No applicator present, but applicator mode is set.
Set SIGNAL INTERFACE > Interface mode to "PLC interface".
Applicator is jammed
Eliminate the obstruction
Compressed air applicator: compressed air supply is interrupted or switched off
Check the compressed air connection and if necessary connect it correctly
Cable not correctly connected.
Check the cable and if necessary connect it correctly.
5201 Touch down
The applicator has not reached its lower end position (touch down) within the assigned
time period. This message can only occur in applicator mode.
No applicator present, but applicator mode is set.
Set SIGNAL INTERFACE > Interface mode to "PLC interface".
Applicator is jammed
Eliminate the obstruction
Compressed air applicator: compressed air supply is interrupted or switched off
Check the compressed air connection and if necessary connect it correctly
Cable not correctly connected.
Check the cable and if necessary connect it correctly.
6002 New prog. vers.
New firmware has been loaded. The dispenser is reporting by way of this message
that new firmware is present.
Press the online key to confirm.
All parameters are reset to the factory setting.