Specifications
7
■ TURN UNIT OFF/ON — Press the ON/OFF button
on the remote control or control panel.
NOTE: To switch from Celsius to Fahrenheit,
press the UP ARROW and DOWN ARROW buttons on
the control panel (not the remote control) at the same
time.
■ COOLING MODES — The air conditioner can be
set to three different cooling modes — Cooling, Fan
Only, or Energy Saving. Press the MODE button to
change the mode.
In Cooling mode, the air conditioner will run and pro-
vide cooling. The amount of cooling can be adjusted
with the FAN SPEED button. If the fan speed is set to
Auto mode, the fan speed adjusts automatically from
low to high based on the setting of the thermostat and
the actual room temperature.
In Fan Only mode, the fan operates to circulate the air
in the room, but there is no cooling operation. This
mode is used to circulate the air in the room when
cooling is not required. The amount of circulation can
be adjusted with the FAN SPEED button. Auto. can-
not be selected in Fan Only mode.
In Energy Saving mode, the air conditioner will auto-
matically switch from Cooling to Fan Only mode when
cooling is not required. Fan speed cannot be selected in
Energy Saving mode. When the room temperature is
2 degrees higher than the thermostat setting, the air
conditioner will run in Cooling mode. When the room
temperature is lower than 66 F, the unit will turn off
(no cooling or fan). At all other times, cooling will be
off and the fan will run on Low speed.
■ FAN SPEED — The air conditioner Fan mode can be
set to High, Medium, Low, or Auto. Press the FAN
SPEED button to change fan speed.
High fan mode is recommended for very warm days or
when a fast initial cooling of the room is desired.
Medium fan mode is recommended on moderately
warm days or when the unit has been operating for
some time and the temperature is about to reach its
desired setting. Low fan mode is recommended on
slightly warm days or after the room temperature has
reached its desired setting. Auto mode adjusts the fan
speed automatically from low to high based on the set-
ting of the thermostat and the actual room tempera-
ture. Auto mode can only be used in Cooling mode.
■ THERMOSTAT — The temperature setting on the
thermostat can be adjusted from a range of 66 to 88 F
(19 to 31 C). The air conditioner will start and stop
cooling operation in order to maintain the temperature
setting of the thermostat.
Press the Down Arrow button to lower the tempera-
ture setting. Press the Up Arrow button to raise the
temperature setting.
F
F
HR
HR
Indication symbols of LED on control panel:
HIGH FAN SPEED
MEDIUM FAN
SPEED
LOW FAN SPEED
AUTO FAN SPEED COOLING
FAN ONLY
DISPLAY SET TEMP
DISPLAY SET TIMER
TIMER
ABOVE LED LIGHTS ON WHEN THE RELEVANT MODE IS IN USED.
ENERGY-SAVING
TIMER
FAN
SPEED
MODE
ON/OFF
MODE
FAN
SPEED
TIMER
ON/OFF
CONTROL PANEL
REMOTE CONTROLLER
FIGURE 11 — ELECTRONIC CONTROLS