Specifications
ELECTRICAL CORD LENGTHS
Connexus™ modules come with pre-determined electrical cord lengths that are suited to the size and con
guration of each table (16’
& 25’). Each will plug into a standard
oor monument power source. However, in situations where a table length exceeds our maximum
cord length, a second power entry is necessary to avoid daisy-chaining of electrical power. To determine when a second power entry
is required follow these steps:
1. Select your Connexus™ locations.
2. Select your Floor Monument Location(s) if they do not already exist in the room.
3. If the number of Connexus™ modules exceed three consecutive positions left or right of the power entry, then an additional
p
ower entry will be required.
Note: Connexus™ modules in pairs count as one position.
CONNEXUS™ | PLANNING
HARDWIRING ON SITE
For hardwiring on-site by electricians, please use the following schematic:
1 Power Supply Cord
2 Strain Relief
3 Fork Terminals
4 Duplex Receptacles
5 Outlets with Circuit Breaker Assembly
6 Handy Box
2
6
1
3
TWO GANG BOX
GREEN
12// AWG
BLACK
WHITE
GREEN
WHITE DECORA DUPLEX
WIRING DIAGRAM
''12// AWG
BLACK WIRE - BRASS SCREW\
WHITE WIRE - SILVER SCREW
GREEN WIRE - GREEN SCREW
REMOVE 4 PLASTER EARS
4
1
5
GREEN
BLACK
BLACK
WHITE
WHITE
BLACK
WHITE
BOX GROUND
CIRCUIT BREAKER/OUTLETS ASSEMBLY