USER MANUAL MODEL 590A and MODEL 591A RS-232 to RS-232 Optical Isolators Part # 07M59XA-C Doc.
TABLE OF CONTENTS 1.0 1.1 1.2 1.3 Warranty Information .................................................................. 3 FCC Information ........................................................................... 3 CE Notice...................................................................................... 3 Service.......................................................................................... 4 2.0 2.1 2.2 General Information..............................................................
1.0 WARRANTY INFORMATION Patton Electronics warrants all Model 590A/591A components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment. This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above.
1.3 SERVICE All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Service at: Tel: (301) 975-1007 E-mail: support@patton.com URL: www.patton.com Note Packages received without an RMA number will not be accepted.
2.0 GENERAL INFORMATION Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Year parts and labor. If any questions or problems arise during installation or use of this product, please do not hesitate to contact Patton Electronics Technical Support at (301) 975-1007. 2.1 FEATURES • Asynchronous • Full or Half Duplex Operation • Supports Data Rates to 19.2 kbps (Model 590A) or 115.
3.0 CONFIGURATION The Model 590A/591A is equipped with two eight-position DIP switches that allow configuration to a wide range of applications. This section describes all possible configuration settings, including the factory default settings. 3.1 CHECKING THE DEFAULT CONFIGURATION The Model 590A/591A passes four optically isolated signals between the connected RS-232 DCE and DTE devices. The data signals, TD (pin 2), and RD (pin 3), have been dedicated and cannot be changed.
Before opening the Model 590A/591A’s case, check the default control signal settings (shown below). If the default configuration is correct, move to Section 4.0 of this manual. Otherwise, proceed to section “Setting the Internal Switches” to change the control signal settings. DCE Side DTE Side DTR (20) Control Signal 1 (20) DTR or RTS (4) (4) RTS CD (8) (8) CD or Control Signal 2 DSR (6) (6) DSR or CTS (5) (5) CTS *NOTE: Default control signals are shown above in bold italics 3.
The two sets of DIP switches on the underside of the Model 590A/591A will be referred to as S1 and S2. Figure 2 shows the orientation of DIP Switches S1 and S2 with respect to “ON” and “OFF” positions. ON ON 1 2 3 4 5 6 7 OFF 8 Figure 2. Close-up of DIP Switches Showing ON/OFF Positions Selecting the DTE Output Signals (DTR or RTS) Use Switches S1-1, S1-2, S2-1 and S-2-2 to connect either Data Terminal Ready (DTR - pin 20) or Request to Send (RTS - pin 4).
3.3 SELECTING THE DCE OUTPUT SIGNALS (CTS, DSR, OR CD) Use Switches S1-3, S1-4, S1-5, S2-3, S2-4, and S2-5 to connect either Clear to Send (CTS - pin 5), Data Set Ready (DSR - pin 6), or Carrier Detect (CD - pin 8. In the “Isolated” setting, the selected signal passes through Model 590A/591A isolated up to 2500VRMS.
4.0 INSTALLATION S/N 1 2 3 4 5 6 78 Model 590 RS-232 Opto-Isolater DTE DCE Connect to “DTE” Gaithersburg, Maryland The Model 590A/591A provides 2500VRMS optical isolation between a DTE and a DCE device. It plugs directly into the DTE and connects to the DCE by a short cable. No additional power is required in most cases. Refer to the diagram below and follow the instructions to install the Model 590A/591A. Connect to “DCE” Figure 3. Model 590A/591A DTE and DCE connector locations 1.
APPENDIX A MODEL 590A/591A SPECIFICATIONS A.1 TRANSMISSION FORMAT Asynchronous, full or half duplex A.2 INTERFACE STANDARD EIA RS-232-E A.3 CONNECTORS Two DB-25 Female A.4 DATA RATES • Up to 19,200 bps (Model 590A) • Up to 115.200 bps(Model 591A) A.5 ISOLATION 2500VRMS A.6 POWER SUPPLY Interface Powered; Optional power supplied to pin 9 (either side) at +9 VDC at 10mA A.7 COMPLIANCE 89/336/EEC, FCC Part 15, Class A A.8 DIMENSIONS 3.8L x 2.1W x 0.79H in. (9.7L x 5.3W x 2.0H cm) A.
APPENDIX B MODEL 590A/591A PIN ASSIGNMENTS DIRECTION To Model 59XA DIRECTION RS-232 Female “DCE” SETTING 1- (FG) Frame Ground 2- (TD) Transmit Data 3- (RD) Receive Data 4- (RTS) Request to Send 5- (CTS) Clear to Send 6- (DSR) Data Set Ready 7- (SG) Signal Ground 8- (DCD) Data Carrier Detect 9- External Power Data Term.