Product data
8
AIR DELIVERY — NOMINAL CFM at up to 0.70 i.w.c. E.S.P. (With filter)
GAS HEAT AIRFLOW
AC/HP JUMPER POSITION: AC AIR CONDITIONING, COOLING AIRFLOW
HP — EFFY HEAT PUMP — EFFICIENCY, COOLING AND HEATING AIRFLOW
HP — CFMT HEAT PUMP — COMFORT, COOLING AIRFLOW
AC/HP JUMPER POSITION: HP — CMFT HEAT PUMP — COMFORT, HEATING AIRFLOW
* Within ± 2°F
† Minimum airflow is set for electronic air cleaner: 060—500 CFM, 080—500 CFM, 100—700 CFM, 120—700 CFM
‡ Use only listed jumper position combinations.
** Maximum available ESP is 0.70 iwc for all furnace model sizes and operating modes, except maximum available ESP is 0.50 iwc for HI cool size airflow at
400 cfm per ton selection with the 080 size furnace.
NOTES:
1. A humidistat can be used to further reduce airflow when increased humidity is sensed. This feature reduces the selected airflow by 20%, but no lower than
280 CFM per ton.
2. Continuous-fan selections are 50%, 65%, or 100% of selected cooling airflow. 100% is not recommended for 2-speed air conditioning or heat pumps.†
3. See the following airflow curves for CFM versus ESP at 350 CFM per ton.
4. Airflow shown is with factory supplied 1-in. washable filter(s). An airflow reduction of up to 7% may occur when using the factory-specified 4 5/16-inch wide, high-effi-
ciency media filter. For best furnace efficiency when using the 4 5/16-inch wide media filter, adjust the blower speed tap to near the mid-point of the rise range.
FURNACE
SIZE
GAS HEAT
TEMP RISE
GAS HEAT
TEMP RISE (°F)*
GAS HEAT
AIRFLOW (CFM)JUMPER POSITION‡
Red Wire Violet Wire HIGH-STAGE LOW-STAGE HIGH-STAGE LOW-STAGE
060
HI
M-HI
MID
A
A
D
51
46
40
45
38
30
925
1085
1250
615
730
1135
080
HI
M-HI
MID
A
A
D
58
51
45
44
39
29
970
1140
1310
790
925
1395
100
HI
M-HI
MID
A
A
D
51
45
40
44
39
30
1430
1685
1935
1035
1215
1630
120
HI
M-HI
MID
A
A
D
69
59
55
49
43
40
1330
1560
1720
1240
1460
1605
FURNACE
SIZE
AIRFLOW
SELECTION
SINGLE-SPEED
CFM
TWO-SPEED (HIGH / LOW)
CFM
COOL SIZE
TONS
COOL CFM PER TON COOL CFM PER TON JUMPER POSITION
JUMPER JUMPER POSITION 400 350 315
POSITION 400 350 315 HIGH LOW HIGH LOW HIGH LOW
060
LO
M-LO
M-HI
HI
1-1/2
2
2-1/2
3
600
800
1000
1200
530
700
880
1050
500†
630
790
945
630
865
1060
1260
500†
510
650
780
550
735
920
1100
500†
500†
570
680
500†
660
825
990
500†
500†
510
585
080
LO
M-LO
M-HI
HI
2-1/2
3
3-1/2
4
1000
1215
1400
1600**
875
1050
1225
1400
790
945
1100
1250
1050
1260
1470
1635**
660
790
910
1040
920
1100
1280
1470
595
700
805
915
830
990
1155
1325
545
625
715
820
100
LO
M-LO
M-HI
HI
3
3-1/2
4
5
1195
1400
1600
2000
1045
1225
1400
1750
950
1090
1260
1575
1260
1470
1680
2085
780
910
1040
1300
1090
1285
1465
1840
775
830
915
1150
990
1155
1325
1655
700†
715
820
1025
120
LO
M-LO
M-HI
HI
3
3-1/2
4
5
1160
1400
1600
2000
1050
1220
1395
1750
955
1090
1250
1565
1195
1420
1650
2110
865
970
1070
1300
1085
1265
1465
1835
785
875
975
1140
985
1150
1315
1640
785
845
930
1080
FURNACE
SIZE
AIRFLOW
SELECTION
SINGLE-SPEED
CFM
TWO-SPEED (HIGH / LOW)
CFM
COOL SIZE
TONS
COOL CFM PER TON COOL CFM PER TON JUMPER POSITION
JUMPER JUMPER POSITION 400 350 315
POSITION 400 350 315 HIGH LOW HIGH LOW HIGH LOW
060
LO
M-LO
M-HI
HI
1-1/2
2
2-1/2
3
540
720
900
1080
500†
630
790
945
500†
570
710
855
565
780
945
1135
500†
500†
585
700
500†
660
830
990
500†
500†
515
610
500†
595
740
895
500†
500†
500†
555
080
LO
M-LO
M-HI
HI
2-1/2
3
3-1/2
4
900
1080
1260
1440
785
945
1100
1260
710
850
990
1135
945
1135
1325
1510
605
715
830
940
825
990
1150
1325
535
630
725
825
755
895
1040
1190
500†
560
655
740
100
LO
M-LO
M-HI
HI
3
3-1/2
4
5
1075
1260
1440
1800
940
1100
1260
1575
855
990
1130
1420
1130
1325
1510
1890
700
820
935
1170
980
1155
1320
1655
700
750
825
1035
890
1040
1190
1490
700†
700†
740
920
120
LO
M-LO
M-HI
HI
3
3-1/2
4
5
1045
1260
1440
1800
945
1100
1255
1575
860
980
1125
1410
1075
1280
1485
1900
780
875
965
1170
975
1140
1320
1650
750
790
880
1025
885
1035
1185
1475
750
760
835
970