Specifications
7
PLUMBING
All of the plumbing components are attached to the case at the factory; therefore, no assembly is required. The case drain
is located front-and-center of the cases for convenient access and is made of cast metal. The āPā trap, furnished with
the case, is made from PVC pipe. Should any future maintenance issues arise, care should be given to assure that all
connections are water-tight and sealed with the appropriate PVC cement and primer.
The case run-off is channeled to a condensate pump located underneath the case as shown below. The water is then
pumped to an evaporative drain pan on top of the case, where an electric heater evaporates the run-off. When cleaning
the case, be sure not to introduce water faster than the drain pump can carry it away.
CONDENSATE
PUMP
MODEL
ONNA-3'
EVAPORATIVE
DRAIN PAN
NOTE: When cleaning the case, do not introduce water
faster than the drain pump can carry it away.