Specifications

APPENDIX A -- LOCAL DISPLAY AND CCN TABLES (cont)
MODE -- CONFIGURATION
ITEM
CONFIGURATION
DISP
METR
LANG
PROT
PSWD
TEST
UNIT
S.DLY
U.CTL
T.CTL
OC.FN
IDF, F
EC.EN
FN,SW
FL,SW
FS.SW
RM.SW
SAT.T
SAT.H
RAT.S
RH.S
RH.SW
TCS.C
TCS.H
COOL
N.CIR
N.A
MRT.C
MOT.C
RST.C
C.DEC
CJNC
FOD.C
DA.LO
CB.LO
CC.LO
ALM.N
SAT
SA.PD
SA.ND
SAT.U
SAT.L
SPT
CLPD
CLND
C.LAG
CIR,A
CS.A1
CS.A2
AI.FN
A2.FN
A3.FN
LEGEND
EXPANSION
Display Configuration
Metric Display
Language Selection
Password Enab]e
Service Password
Test Display LEDs
Unit Configuration
Start Up Delay
Unit Control Type
Thermostat Control Type
Fan On When Occupied
Shut Down on IDF Failure
Economizer Installed
Fan Status Switch
Filter Status Switch
Fire Shutdown Switch
Remote Occupancy Switch
SAT Settling Time
SAT Heat Mode Sensing
RAT Sensor On SPTO input
RH Sensor ON OAQ input
Space Humidity Switch
Tamp Crop Strt Cool Factr
Tamp Crop Strt Heat Factr
Cooling Configuration
Number of Circuits
Compressors on Circuit A
Compressor Min On Time
Compressor Min Off Time
Runtime to Reset Strikes
Cool Stage Decrease Rate
Cool Stage increase Rate
Fan-off Delay, Mech Cool
Circuit A Lockout Temp
Circuit B Lockout Tamp
RANGE UNITS DEFAULT
On/Off Off
0=English O
1=Spanish
2=French
3=Portuguese
Enable/Disable Enable
9090 to 9999 1111
On/Off Off
O to 600
1=Auto Select
2=Thermostat
8=Space Sensor
0=Adaptive
1=1 Stage Y1
2=2 Stage Y1
Yes/No
Yes/No
Yes/No
0=No Switch
1=Normally Open
2=Normally Closed
O=No Switch
l=Normaily Open
2=Normally Closed
O=No Switch
1=Normally Open
2=Normally Closed
0=No Switch
1=Normally Open
2=Normafly Closed
I 0 to 900
Enable/Disable
Yes/No
Yes/No
0=No Switch
1=Normal Open
2=Normal Closed
Oto6O
Oto6O
1 to3
1 to2
120 to 999
300 to 999
120 to 999
120 to 999
120 to 999
O to 600
0to 1OO
0to 1OO
mins
mins
30
2
Yes
Yes
No: no FlOP
Yes: FlOP
0: no FlOP
1: FlOP
0: no FlOP
1: FlOP
0: no FlOP
1: FlOP
240
Disable
No
No
0: no Humidi-MiZer FlOP
1: HumidFMiZer FlOP
2
1
sac 180
sac 300
sec 300
sac 300
sac 450
60sec
dF g
dF 0: no Humidi-MiZer FlOP
HumidFMiZer FLOP:
CCN TABLEISUB-TABLE
SERVICE CONFIGURATION
DISPLAY
UNIT
COOL_CFG
CCN POINT
DiSPUNIT
LANGUAGE
PASS EBL
PASS_VORD
DtSPTEST
STARTDLY
CTL_TYPE
STATTYPE
OCC FAN
FATA[FAN
ECONO
FANSTCFG
FILSTCFG
SHTDNCFG
REMOCCFG
SAT_SET
SAT_HEAT
RAT_SPTO
RH_OAQ
HUMSTCFG
TCSTCOOL
TCSTHEAT
NUM CIRC
A COMPS
M_N_ON
MIN_OFF
MIN ON S
STAGEDEC
STAGEINC
COOL_FOD
OATLCMPA
OATLCMPB
Circuit C Lockout Temp
Alert Each Strike
Supply Air Temperature
SAT Cool Demand (+) Level
SAT Cool Demand (-) Level
Minimum SAT Upper Level
Minimum SAT Lower Level
Space Temperature
SPT Cool Demand (+) Level
SPT Cool Demand (-) Level
Cool Thermal Lag Factor
Circuit A
A1 Current Sensing
A2 Current Sensing
0 to 100
Yes/No
0.5 to 10
-10 to -0.5
35.0 to 65.0
350 to 65.0
0.5 to 5
-5 to -05
Oto5
Enable/Disable
Enable/Disable
^F
^F
dF
dF
^F
^F
rain
o
o
Yes
1
-1
58
48
Disable (1-phase)
Enable (3-phase)
Disable
OATLCMPC
ALM_NOW
SAT_POS
SAT NEG
SAT_4iN_H
SATMiN_L
DEM_POS
DEM NEG
COO__LAG
AI_SENSE
A2 SENSE
A Circuit Level 1 Fans
A Circuit Level 2 Fans
A Circuit Level 3 Fans
0to7
0to7
0to7
1: No Humidi-MiZer FlOP
(20, 24)
5: No Humidi-MiZer FlOP
(28)
1: HumidFMiZer FlOP
No Humidi-MiZer FlOP
3 (20)
2 (24, 28)
Humidi-MiZer FlOP
3 (20)
2 (24, 28)
No Humidi-MiZer FlOP
3 (20, 24)
7(28)
HumidFMiZer FlOP
3
CIR_A_3
PAGE NO.
39
35, 39, 41,
43.47
38. 39, 41
39, 41, 43
40, 56
40.41
40. 56, 82
40, 82
38, 40
38, 40
40_ 42
40_ 44
40. 82
35. 38, 40,
47. 82
35, 38, 40,
47. 82
40. 51
40.41
56
56
41.42
41.42
4I, 42
41.42
FlOP -- Factory-lnstaNed Option
p?