Solid-state Timer H3BA-N Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and Application Considerations (page 20), and Safety Precautions (page 16). Solid-state Timer with Valuable Multiple-time Ranges and Multiple-operating Modes • Handles a wide range of applications through six operating modes.
Model Number Structure ■ Model Number Legend H3BA-N@ 1 1.
Specifications ■ General Item H3BA-N H3BA-N8H A: ON-delay H: ON-delay with instantaneous output contact Operating mode A: ON-delay B: Flicker OFF start B2: Flicker ON start C: Signal ON/OFF-delay D: Signal OFF-delay E: Interval Pin type 11-pin 8-pin Input type No-voltage input --- Output type DPDT (time-limit) SPDT (time-limit) and switchable SPDT (time-limit <---> instantaneous) Mounting method DIN track mounting, surface mounting, and flush mounting Approved standards UL508, CSA C22.2 No.
■ Characteristics Item H3BA-N H3BA-N8H Accuracy of operating time ±0.3% FS max. ( ±0.3%±10 ms in a range of 1.2 s) Setting error ±5% FS ±0.05 s max. Reset time Min. power-opening time: 0.1 s max. Min. pulse-input time: 50 ms Influence of voltage ±0.5% FS max. ( ±0.5%±10 ms in a range of 1.2 s) Influence of temperature ±2% FS max. (±2%±10 ms in a range of 1.2 s) Insulation resistance 100 MΩ min.
Operation ■ Block Diagrams H3BA-N AC (DC) input Power supply circuit Oscillation circuit Reset input, start input, and gate input Time range/ unit selectors Operating mode selector Counting circuit Output circuit Indicator circuit Input circuit Power-ON Output-ON indicator indicator H3BA-N8H AC (DC) input Power supply circuit Oscillation circuit Time range/ unit selectors Output type selector Counting circuit Output circuit Indicator circuit Power-ON Output-ON indicator indicator Instanta
■ Basic Setting ■ Using the Setting Ring Setting of Selector Setting a Specific Time The selectors can be turned clockwise and counterclockwise to select the desired time unit, time range, output type (only for H3BAN8H) or operating mode. Each selector has a snap mechanism that secures the selector at a given position. Set the selector at a position at which it is secured. Do not set it midway between two securing positions or a malfunction could result from improper setting.
■ Timing Chart Note: 1. The minimum power-opening time (“Rt”) is 0.1 s and the minimum pulse width is 0.05 s. 2. The letter “t” in the timing charts stands for the set time and “t–a” means that the period is less than the time set.
Operating mode Timing chart D: Signal OFF-delay t-a t-a t t-a t Power 2 and 10 Start 2 and 6 Reset 2 and 7 Output relay 1 and 4 (11 and 8) (NC) Output relay (NO) (Output indicator) 1 and 3 (11 and 9) Power indicator Basic operation Power Start t Output E: Interval t t t-a t Power 2 and 10 Start 2 and 6 Reset 2 and 7 Output relay 1 and 4 (11 and 8) (NC) Output relay (NO) (Output indicator) 1 and 3 (11 and 9) Power indicator Basic operation Power Start t Output Gate Signal Input in Operati
H3BA-N8H, Output Type: A Type Operating mode Timing chart A: ON-delay Rt t Rt t t-a Power 2 and 7 Output relay (NC) 8 and 5 (1 and 4) Output relay (NO) 8 and 6 (1 and 3) and output indicator Power indicator Basic operation Power t Output H3BA-N8H, Output Type: H Type Operating mode H: ON-delay with instantaneous output contact Timing chart Rt t t Rt t-a Power 2 and 7 Output relay 8 and 5 (NC) Output relay 8 and 6 (NO) (output indicator) Instantaneous 1 and 4 output relay (NC) Instantaneous
Dimensions Note: All units are in millimeters unless otherwise indicated. H3BA-N 15 78 63.7 6 48 0.7 13.6 PW UP 44.8 × 44.8 39 dia. 48 11 pins H3BA-N8H 15 78 6 63.7 48 0.7 13.6 PW UP 44.8 × 44.8 39 dia. 48 8 pins Dimensions with Set Ring 16.5 50 42 dia. 50 Time setting ring Panel cover Dimensions with Y92F-30 Flush Mounting Adapter Panel P3G Back Connecting Socket (sold separately) PW UP 58 52 42 48 Panel Cutout Note: The mounting panel thickness should be 1 to 5 mm. 0.
Dimensions with Y92F-70 Flush Mounting Adapter Panel Cutout Panel Adapter mounting hole Two, 4.5 dia. 52 to 53 R0.5 max. 45± 88 0.15 PW UP 65 to 66 76±0.2 45±0.15 58 Dimensions with Y92F-71 Flush Mounting Adapter Panel 56 R0.5 max. 45 +0.5 −0 PW UP 58 55 +0.5 −0 68 45±0.2 43±0.2 50 +0.2 −0 Track Mounting Note: The mounting panel thickness should be 1 to 3.2 mm. Flush Mounting 15 H3BA-N 112.2* H3BA-N8H 109.9 101.3* 99 15 91.4 86.
■ Accessories (Order Separately) Track Mounting/Front Connecting Socket P2CF-08 Eight, M3.5 × 7.5 sems 3 7.8 Terminal Arrangement/ Internal Connections (Top View) 4.5 Surface Mounting Holes Two, 4.5 dia. or two, M4 70 max. 35.4 Two, 4.5 dia. holes 40±0.2 4 50 max. 20.3 max. P2CF-11 Eleven, M3.5 × 7.5 sems 3 4.5 Two, 4.5 dia. or two, M4 7.8 40±0.2 70 max. 35.4 Two, 4.5 dia. holes 4 50 max. 31.2 max.
End Plate Time Setting Ring/Panel Cover PFP-M 10 6.2 1 50 1.8 1.8 35.5 35.3 There are three types of Panel Covers (Y92P-48GL, Y92P-48GB, and Y92P-48GM), all of which are available in three colors. Use the most suitable type of Panel Cover with the design of the scaling plate according to the application. When setting a given time for the Timer, use of the Y92S-27 or Y92S-28 Time Setting Ring facilitates the time setting operation and minimizes possible setting errors by operators.
Installation ■ Terminal Arrangement Gate input Start input Reset input H3BA-N (Contact Output) (–)(~) Power supply (+)(~) H3BA-N8H (Contact Output) Note: The delayed contacts of conventional timers are shown as follows: The contact symbol of the H3BA-N is expressed as follows because of its multiple operating modes: H A MODE (See note.
■ Input Connections The inputs of the H3BA-N are no-voltage (short circuit or open) inputs. No-voltage Inputs No-contact Input (Connection to NPN open collector output sensor.) 12 to 24 VDC (sensor power supply) Sensor Contact Input No-contact Input (Connection to a voltage output sensor.) 12 to 24 VDC (sensor power supply) + DC power − supply + DC power − supply Timer Timer Timer Sensor Start/reset/ gate Start/reset/ gate Start/reset/ gate Input (0 V) (No. 2 pin) Input (0 V) (No.
Safety Precautions CAUTION Minor electric shock may occasionally occur. Do not disassemble the product or touch the interior of the Timer. Minor burns may occasionally occur. Do not touch the product while power is being supplied or immediately after power is turned OFF. Minor fires may occasionally occur. Tighten terminal screws to a torque of 1.08 N·m so that they do not become loose. Minor electric shock may occasionally occur during operation. Install the terminal cover.
Operating Time Setting ■ Mounting When setting the operating time, do not turn the setting knob beyond its scale range. For precise time setting, conduct operation tests by adjusting the setting knob. Surface Mounting The accuracy of the operating time of the Analog Timer is indicated by the percentage value on the basis of the full-scale time. The absolute fluctuation value will not be improved by changing the time setting.
■ Dismounting PL Socket 1. Secure the Socket to the panel surface with screws and insert the F-shaped hook into the sockets. Surface Mounting with P2CF 2. Connect the Timer to the Socket and press the tip of each hook by hand. Panel Mounting Loosen the screws of the Flush Mounting Adapter, spread open the hooks, and remove the Mounting Adapter.
Solid-state Timer H3BA-N 19
Terms and Conditions of Sale 1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed part of all quotes, agreements, purchase orders, acknowledgments, price lists, catalogs, manuals, brochures and other documents, whether electronic or in writing, relating to the sale of products or services (collectively, the "Products") by Omron Electronics LLC and its subsidiary companies (“Omron”).
Note: This datasheet is provided as a guideline for selecting products. Do not use this document to operate the Unit. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ELECTRONICS LLC • THE AMERICAS HEADQUARTERS Schaumburg, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com OMRON CANADA, INC. • HEAD OFFICE OMRON ARGENTINA • SALES OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.