The operation and maintenance instructions for the indoor unit and the installation instructions for the indoor and the outdoor unit are given in the manuals for each unit. These are supplied with the unit. Contents Page Dimensions and weight............................................................................... 2 Nominal data ............................................................................................... 2 Minimum clearances ....................................................
42VMC Dimensions and weights - Minimum clearances (mm) Dimensions and weights Minimum clearances Wall installation A B 500 min 200 50 min 40 Ceiling installation Ø 80 50 50 min Model 42VMC009 42VMC012 42VMC014 42VMC018 42VMC024 A mm 850 850 1000 1000 1000 B mm 540 540 600 600 600 kg kg 15 16 18 18 20 Table I: Nominal data POWER INPUT Cooling only • Unit is not suitable for operation in laundry premises.
2VMC Connections ENGLISH 햳 햲 햳 햴 햴 햴 햲 햳 햲 Note: Height difference / Connection length / Pipe bends: See outdoor unit installation manual.
42VMC General information Unit installation Read this instruction manual thoroughly before starting the installation. • This unit complies with low-voltage (EEC/73/23) and electromagnetic compatibility (EEC/89/336) directives. • Failure to observe electric safety codes may cause a fire hazard in case of short circuits. • Inspect equipment for damage due to improper transportation or handling: file an immediate claim with the shipping company. Do not install or use damaged units.
42VMC Warnings: avoid… ENGLISH ...any obstruction of the unit air outlet or return. ...exposure to direct sunshine, when unit is operating in cooling mode; always use shutters or shades.. ...positions too close to heating sources which may damage the unit. ...exposure to oil vapours. ...connecting condensate piping to sewage system drain without appropriate trap. Trap height must be calculated according to the unit discharge head in order to allow sufficient and continuous water evacuation. ...
42VMC Installation Vertical wall-mounting Hole Plate Template • The preferred arrangement is generally under a window sill on an external wall. This makes it easier to install the interconnecting tubing, electrical connections and condensate pipework to the outdoor unit. The indoor unit can also be installed against an internal partition if the connections to the outdoor unit can be concealed.
42VMC Installation ENGLISH Drilling the hole in the wall for the connection of the pipes For horizontal installation To allow the condensate drain pipe to correctly come out of the unit, proceed as follows: 75 mm Ø 80 mm 50 mm 햲 Ø 70 / 80 mm 5-10 mm The pipes can exit the unit to three different directions (see illustration). For exit to the rear, the wall hole must be made in the position shown in the illustration.
42VMC Refrigerant connections Make refrigerant connections before connecting the system to the power supply. Refer to the outdoor unit installation manual for tube sizing, and limitations (slopes, length, number of curves allowed, refrigerant charge, etc.) Model mm 009 012 014 018 024 9.52 12.70 12.70 12.70 12.70 Connection to the unit Insufficient tightening torque will cause gas leaks. Overtightening the fittings will damage the tube flaring and cause gas leaks.
42VMC Electrical connections ENGLISH The mains supply must be connected as follows: Models 42VMC 009, 012, 014: to the indoor unit. Models 42VMC 018, 024: to the outdoor unit. • Make electrical connections between units prior to proceeding to mains supply unit connection. • Before proceeding with the unit connection to the mains supply locate live L and neutral N, then make connections as shown in the wiring diagram.
42VMC Electrical connections Cooling only 42VMC 009, 012, 014 Unit System 쐃 L N N Y O W2 230V ~ 50Hz L N N Y O W2 쐋 쐏 N Y 쐇 햳 햲 42VMC 018, 024 Unit System 쐃 C Y O W2 S R C Y O W2 S 230V ~ 50Hz R 쐋 쐏 L N R C Y 쐇 햳 Minimum connection wire size between indoor and outdoor units (mm2) Model N R C Y 42VMC 009 2.5 2.5 1.5 – – 1.5 2.5 2.5 2.5 – – 2.5 42VMC 018, 024 – – – 1.5 1.5 1.5 Earth. Live power supply. Neutral power supply.
42VMC Electrical connections ENGLISH Heat pump 42VMC 009, 012, 014 Unit System 쐃 N N Y O W2 L N N Y O W2 230V ~ 50Hz L 쐋 쐏 N Y O W2 쐇 햳 햲 42VMC 018, 024 Unit System 쐃 C Y O W2 S R C Y O W2 S 230V ~ 50Hz R 쐋 쐏 L N R C Y O W2 S 쐇 햳 햳 Minimum connection wire size between indoor and outdoor units (mm2) Model L N N R C Y O W2 S 42VMC 009 2.5 2.5 1.5 – – 1.5 1.5 1.5 – 42VMC 012, 014 2.5 2.5 2.5 – – 2.5 2.5 2.5 – 42VMC 018, 024 – – – 1.5 1.5 1.5 1.5 1.
42VMC System configuration System configuration Cooling only configuration (of the remote controller) Units are factory configured as heat pumps. When a cooling only system is installed, it is necessary to change the factory configuration. Such operation must be performed by the installer as follows: Cooling only configuration (of the system) • • • • • • • • • Check all electrical connections (instructions and wiring diagram). Insert the batteries into the remote control and leave it OFF.
42VMC Operating test, address selector, fault code, guide for the owner and accessories ENGLISH Operating test Fault code • Perform the operating test after the units have been installed in position and the gas leak test has been completed. • Check all electrical connections (instructions and wiring diagram). • Insert the batteries into the remote control and leave it OFF. • Energise the system, turning the power supply ON.
42VMC Air delivery and fresh air renewal Air delivery direction Wall installation, cooling Wall installation, heating Ceiling installation, cooling Ceiling installation, heating “No draught” (guide vane fully open) (position recommended for ceiling installation in cooling mode, to avoid draughts) IMPORTANT: Air is supplied into the room through the grilles located on top of the cabinet; air from the room is drawn into the unit through the grilles and filter at the bottom of the unit.