Duct Split System Data Sheet

8
SPECIFICATIONS
System
Size 9 12 18 24 36 48
Outdoor Model 38MAQB09---3 38MAQB12---3 38MAQB18---3 38MAQB24---3 38MBQB36---3 38MBQB48---3
Indoor Model 40MBQB09D--3 40MBQB12D--3 40MBQB18D--3 40MBQB24D--3 40MBQB36D--3 40MBQB48D--3
Energy Star YES YES YES YES NO NO
Performance
Cooling Rated Capacity Btu/h 9,000 11,000 16,000 23,000 36,000 48,000
Cooling Cap. Range Min - Max Btu/h 3,500~11,000 4,000~13,000 4,500~18,000 5,500~24,500 8,500~38,000 9,000~50,000
SEER 19.0 18.0 18.5 19.0 15.5 16.5
EER 13.5 12.5 12.5 12.5 8.5 8.2
Heating Rated Capacity Btu/h 10,000 11,800 18,000 24,400 38,000 50,000
Heating Cap. Range Min - Max Btu/h 4,500~11,500 5,000~13,500 5,500~19,000 6,000~26,000 9,500~50,000 10,000~55,000
HSPF 9.6 9.0 9.6 10.5 10.5 10.0
Controls
Wireles s Remote Controller (°F/°C Convertible) Standard
Wired Remote Controller (°F/°C Convertible) Standard
Operating
Range
Cooling Outdoor DB Mi n - Max °F 4~122 4~122 4~122 4~122 4~122 4~122
Heating Outdoor DB Min - Max °F 4~86 4~86 4~86 4~86 4~86 4~86
Piping
Total Piping Length Ft. 82 82 98 98 213 213
Piping Lift
*
Ft. 32 32 65 65 98 98
Pipe Connection Size - Liquid In. 1/4 1/4 1/4 3/8 3/8 3/8
Pipe Connection Size - Suction In. 3/8 1/2 1/2 5/8 5/8 5/8
Refrigerant
Type R410A
Design Pressure PSIG 550 550 550 550 550 550
Metering Device Capillary Tube in Outdoor Unit
Charge Lbs. 2.76 2.76 4.19 5.18 7.5 9.48
Outdoor
coil
Face Area Sq. Ft. 9.2 9.2 16.0 21.1 8.2 14.1
No. Rows 2 2 2 3 2.6 2.0
Fins per inch 21 21 18 18 17 17.0
Circuits 4 4 6 8 6 10.0
Indoor Coil
Face Area Sq. Ft. 1.4 1.4 1.4 2.0 3.5 4.2
No. Rows 3 3 3 4 4 4
Fins per inch 16 16 16 16 16 16
Circuits 4 4 4 6 8 8
Compressor
Type Hermetic Rotary DC Inverter Compressor
Model ASM98D1UFZA ASM108D1UFZA ASM135D23UFZ DA250S2C-30MT TNB306FPGMC-L MNB36FAAMC-L
Oil Type VG74 VG74 VG74 VG74 FV50S FV50S
Oil Charge Fl. Oz. 12.5 12.5 15.2 27.7 36.2 47.3
Rated Current RLA 5.3 5.7 7.3 8.8 13.5 13.5
Electrical
Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60
Power Supply Indoor unit powered from outdoor unit
MCA A. 15 15 15 15 30 35
MOCP - Fuse Rating A. 15 15 20 25 50 55
Outdoor
Unit Width In. 31.9 31.9 33.3 37.2 37.2 36.9
Unit Height In. 22.0 22.0 27.6 31.9 31.9 53.9
Unit Depth In. 12.2 12.2 12.6 15.6 15.6 15.4
Net W eight Lbs. 82.4 82.4 120.5 134.0 160.9 220.0
Airflow CFM 945 945 1050 1390 2940 4240
Sound Pressure dB(A) 56 56 59 62 65 65
Indoor
Unit Width In. 27.6 27.6 36.2 36.2 44.9 47.2
Unit Height In. 8.3 8.3 8.3 10.6 10.6 11.8
Unit Depth In. 25.0 25.0 25.0 25.0 30.5 34.1
Net W eight Lbs. 39.9 39.9 50.7 57.3 77.2 99.2
Number of Fan Speeds 3 3 3 3 3 3
Airflow (lowest to highest) CFM 290/340/380 290/340/380 400/440/480 590/650/810 680/940/1180 940/1180/1470
Sound Pressure (lowest to highest) dB(A) 30/33/36 30/34/38 34/37/38 43/45/48 46/50/52 41/44/46
Max Static Pressure In.WG. 0.16 0.16 0.28 0.28 0.32 0.40