Installation instructions
6
INSTALLATION TIPS
Ideal installation locations include:
Indoor
Unit
S A location where there are no obstacles near inlet and outlet area.
S A location which can bear the weight of indoor unit.
S Do not install indoor units near a direct source of heat such as
direct sunlight or a heating appliance.
S A location which provides appropriate clearances as outlined in
Fig. 3.
INDOOR UNIT INSTALLATION
INSTALL MOUNTING PLATE
The mounting plate will look like one of the following figures
depending on the model size.
1.8/45
7.1/180
4.3/110
1.4/36.5
1.8/45
11/280
29.5/750
Sizes 09K & 12K
Unit: inch/mm
A150728
Fig. 4 --- Mounting Plate -- Model sizes 09, 12
1.8/45
1.8
/4
5
1.4/36.5
11/280
4.3/110
5.5/140
32.9/835
Size 18K
Unit: inch/mm
A150727
Fig. 5 --- Mounting Plate -- Model size 18
12.4/315
1.8/45
Size 24K
Unit: inch/mm
A150729
Fig. 6 --- Mounting Plate -- Model sizes 24
0.85/21.5
1.8/45
13.5/
3
43
Size 30K & 36K
Unit: inch/mm
A150730
Fig. 7 --- Mounting Plate -- Model sizes 30, 36
1. Carefully remove the mounting plate, which is attached to
the back of the indoor unit.
2. The mounting plate should be located horizontally and level
on the wall. All minimum spacings shown in Fig. 3 should
be maintained.
3. If the wall is block, brick, concrete or similar material, drill
.2” (5 mm) diameter holes and insert anchors for the
appropriate mounting screws.
4. Attach the mounting plate to the wall.
DRILL HOLE IN WALL FOR INTERCONNECTING
PIPING, DRAIN AND WIRING
Refrigerant Line Routing
The refrigerant lines may be routed in any of the four directions
showninFig.9.
For maximum serviceability, it is recommended to have refrigerant
line flare connections and the drain connections on the outside of
the wall that the fan coil can be mounted on.
If piping is going through the back:
1. Determine the pipe hole position using the mounting plate
as a template. Drill pipe hole diameter per values given in
Fig. 4 through 7. The outside pipe hole is 1/2--in. (13 mm)
min. lower than inside pipe hole, so it slants slightly
downward (see Fig. 8).
1/2 in. (13 mm)
Min.
INDOOR
OUTDOOR
A07371
Fig. 8 --- Drill Holes
If piping is going through the right or left side:
1. Us e a sma ll s aw bla de to carefully re m ove t he correspondi ng
plas tic cove r ing on side panel and drill the appr opri at e siz e
hole wher e the pipe is going thr ough the wal l.
Pipe holder
Pipe cover
Right piping
Left piping
Pipe cover
Right back piping
Left back piping
1
2
3
4
A14349
Fig. 9 --- Piping Locations