Operating instructions
Electrical voltage
This pictogram indicates that there are electrical components
behind this access cover, door or panel that may be dangerous
for the user/installer. Only personnel qualified in accordance
with NEN 3140 is permitted to carry out work on these
components. The pictogram is attached to the access cover
for the electric heater control box.
Removal of transport brackets
This pictogram is located at the bottom of the fan section. It
indicates that the transport brackets must be removed during
commissioning before the fan is started up.
Verwijder transportbeugels voor opstarten ventilator.
Remove transport brackets before starting up the fan.
Retirer les fixations de transport avant démarrage.
Central data
This label contains the data for the AHU, such as order
number, position number etc. If present, the label is normally
located on the access cover or the door of the fan assembly.
Opening the fan door
This pictogram is positioned on the outside of the door or
access cover of the fan assembly. This pictogram warns that
the fan must have been switched off and deenergised for a
minimum of two minutes before the door or access cover is
opened.
Lifting and transport
An instruction is attached to the AHU that describes the
procedures that must be followed for lifting and transport.
The following chapter contains further details.
1.4 - Disposal of parts/materials
- The packaging material must be disposed of in a responsible
manner and in accordance with local regulations.
- Components that are replaced, must be disposed of as
described above.
2 - TRANSPORT AND LIFTING INSTRUCTIONS
2.1 - General
Transport and lifting of the AHU must always be in
accordance with the instructions below. If these instructions
are not observed, irreparable damage may occur to the unit,
and people in the immediate vicinity of the unit are also
endangered. Carrier Holland Heating does not accept any
responsibility if these instructions are not observed. Transport
and lifting must be carried out by qualified personnel. The
AHU must only be lifted with lifting bars supplied by
Carrier Holland Heating. Lifting must be carried out in
accordance with local regulations and with the help of
certified lifting aids.
2.2 - Transport and storage
Lifting of the AHU is only permitted under the designated
lifting points. Lifting under the cross beams is prohibited.
This applies to transport as well as storage, and is indicated
on the cross beam with the following label.
! WARNING!
Before opening doors, switch off and deenergise the
fan, and ensure that it has stopped rotating.
(minimum of 2 minutes)
.
5
Caution: All doors and access covers must be closed before
starting up the AHU.