Operator`s manual

Figure 67, Module A15, parts location.
(receptacle for A16) and insert A16
into the module extender.
(2) Prepare Multimeter ME-26B/U.
(3) Set the front panel controls of the
receiver-transmitter as follows:
(a) BAND switch at 30-52.
(b) Tuning knobs to 30.00 mc.
(c) Function switch at ON.
b. Output Voltage Test.
(1)
(2)
(3)
(4)
Connect the ME-26B/U between
pins C and D of A16J1, and note the
voltage.
Connect the ME-26B/U between
A16J2 and ground. The ME-26B/U
should indicate the same voltage as
that in (1) above.
Connect the ME-26B/U between
pins F and D of A16J1. With exactly
+10 volts input, the ME-26B/U
should indicate +9.5 volts dc ±0.5.
With a +15 volts dc input ±0, the
ME-26B/U should indicate +10
volts dc ±0.5.
Connect the ME-26B/U between
A16J3 and ground. The ME-26B/U
should provide the same indica-
tions as given in (3) above.
c. Faulty Parts Location.
(1) Connect A16 to a 12-volt, dc-power
source. Measure the voltages at
the points outlined in the chart in
(2) below. Compare them with the
normal dc voltages listed.
Note: Measure all voltages to ground.
(2) Dc voltage chart.
I
Point
of
measurement
I
Volts
(de)
J1
pill
C
-----------------------
Q1
emitter
--------------------
Q1
collector
-------------------
Q1
bsse
-----------------------
J1
pill
F
-----------------------
Q2
emitter
--------------------
Q2
collector
-------------------
Q2
bsse
------------------—---
12.5
12.2
9.8
12.0
9.8
9.8
4.
‘7
12.0
5.3