Installation guide

AFS
LEGEND
24 VOLT FACTORY WIRING
24 VOLT FIELD WIRING
FIELD SPLICE CONNECTfON
RELAY SPDT, PILOT DUTY
24-V COIL (HN61 KK324)
OR EQUIVALENT
HUMIDISTAT, OPENS ON
HUMIDITY RISE (HL38MG026
AIRFLOW SELECTOR
A01222
WIRING DIAGRAM NOTES:
1. WIRING MUST CONFORM TO NEC OR LOCAL CODES.
2. UNDERLINED LETTER ON THERMOSTAT TERMINAL INDICATES USAGE. FOR EXAMPLE: O/W2 MEANS O IS ENERGIZED
IN COOLING MODE.
3. REFER TO INDOOR UNIT INSTALLATION INSTRUCTIONS FOR ANY ADDITIONAL FEATURES AND WIRING INFORMA-
TION.
4. NON-PROGRAMMABLE MODEL 2S0 I-B, WHEN USED IN AIR CONDITIONING INSTALLATION THE R 19 JUMPER MUST BE
CUT AND REMOVED.
5. PROGRAMMABLE MODEL 2S01-B MUST HAVE DIP SWITCH C ON WHEN USED IN AIR CONDITIONER APPLICATIONS.
6. THERMIDISTAT DIP SWITCH NO. 1 SHOULD BE SET IN OFF POSITION FOR AIR CONDITIONER APPLICATIONS
(FACTORY DEFAULT).
7. AS AN OPTION O/W22CAN CONTROL SECOND-STAGE HEAT.
8. THERMIDISTAT DIP SWITCH NO. 2 SHOULD BE SET IN THE ON POSITION FOR DUAL CAPACITY COMPRESSOR
OPERATION.
9. TO ACTIVATE DEHUMIDIFY FUNCTION ON FK4 OR FV4. REMOVE Jl JUMPER AT FAN COIL CONTROL BOARD.
10. AS AN OPTION, LOCK FURNACE INTO LOW-FIRE OPERATION AND LET O/W2 CONTROL HIGH FIRE OPERATION. REFER
TO FURNACE INSTALLATION INSTRUCTIONS FOR PROPER SETUP.
11. TO ACTIVATE DEHUMIDIFY FEATURE ON CURRENT STYLE, VARIABLE-SPEED, 80 PERCENT NON-CONDENSING,
FURNACE DISCONNECT GREEN (DEHUM) WIRE FROM G ON FURNACE CONTROL BOARD AND CONNECT TO
DEHUMIDIFY TERMINAL DHUM ON THERMIDISTAT.
12. THE DE JUMPERS MUST BE REMOVED TO ENABLE THE DEHUMIDIFICATION FEATURE ON FURNACE.
Table 2--Accessory Usage
REQUIRED FOR REQUIRED FOR
ACCESSORY LONG-MNE SEACOAST
APPUCATIONS* APPUCATIONS
(50-175 FT.) (WITHIN 2 MILES)
Coastal Filter No Yes
Support Feet No Recommended
Puron_ Balance-Port Hard
Shut-off TXV Yest Yes'i"
For tubing line sets between 50 and 175 ;1horizontal or 20 It vertical differential, refer to Application Guideline and Service Manual--Air Conditioners and Heat Pumps
Using Puron@ Refrigerant. Crankcase heater and start assist are standard on twc_speed units.
1"Required for all applications.
9