Specifications

Table 3 -- Physical Data
018 024 030 036
18,000 24,000 30,000 36,000
31 31 51 51
5.4/5.2 7.9/7.9 8.8/9.2 13.0/12.8
R-410A
Accurator Piston at Outdoor Unit
Accurator Piston at Outdoor Unit
6.0 I 6.3 I 7.4 I 10.6
1335/645 1335/645 1030/730 1200/900
1120/525 1120/525 930/630 1050/750
1000/460 1000/460 830/530 900/600
64 64 74 74
1...4.0 x 33.7 1...4.0 x 33.7 2...4.2 x 23.5 2...4.2 x 23.5
3.0 3.0 4.9 4.9
2 2 2 2
16/16 16/20 18/18 18/18
5 5 9 9
2...12.5 x 16.11 2,..12,5 x 16.11 3..,17.3 x 16.11 3..,17.3 x 16.1
Manual I Manual I Automatic I Automatic
Automatic Automatic Automatic Automatic
SYSTEM SIZE
NOMINAL CAPACITY (Btuh)
OPERATING WEIGHT (Ib)
MOISTURE REMOVAL RATE
(Pints/hr) (40QNC/QNQ)
REFRIGERANT
Type
Control Device (Cooling)
Control Device (Heating)
Factory Charge (Ib)*
INDOOR FAN
Rpm/Cfm (High)
Rpm/Cfm (Med)
Rpm/Cfm (Low)
Motor Watts
Blowers Quantity...Size
INDOOR COIL
Face Area (sq ft)
No. Rows
FPI (40QNC/QNQ)
Circuits
FILTERS
Quantity...Size (in.)
AIR SWEEP
Horizontal
Vertical
OPERATING LIMITS
Heating (MiniMax)
Cooling (MiniMax)
CONTROLS
Remote Controller Options
Diagnostics
Defrost Method
Timer Mode
Warm Start Feature
Test Mode
Freeze Protection
Dehumidification Mode
Fan Mode
Auto Changeover
Auto Restart
Control Voltage
System Voltage
REFRIGERANT LINES
Connection Type
Mixed Phase Line (in.) OD
Vapor Line (in.) OD
Max Length (ft)
Max Lift (Fan coil above) (ft)
Max Drop (Fan coil below) (ft)
CONDENSATE DRAIN
Size (in.)
LEGEND
db -- dry bulb
FPI -- Fins Per Inch
ID -- Internal Diameter
wb -- wet bulb
--/81 F db
59 F wb, 70 F db/74 F wb, 90 F db
Integrated Microprocessor
Wireless, CRC, CZM
Yes
Demand Defrost
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
24v
208/230
Flare
3/613/613/613/6
5/8 5/8 3/4 3/4
200
60
60
5/80D, 7/16 ID I 5/80D, 7/1GID I 3/40D, 5/9 ID I 3/40D, 5/9 ID
*Factory charge is based on 25 ft of interconnecting line.