Specifications

40QNC018-036
Cooling Only
40QNQ018-036
Heat Pump
Duct-Free Fan Coil Units
Installation, Start-Up and
Service Instructions
CONTENTS
Page
SAFETY CONSIDERATIONS ...................... 1
GENERAL ........................................ l
INSTALLATION ................................ 1-13
Step 1 -- Complete Pre-lnstallation Checks ...... l
i UNPACK UNITS
i INSPECT SHIPMENT
f CONSIDER SYSTEM REQUIREMENTS
Step 2 -- Mount Unit ............................. 5
Step 3 -- Complete Refrigerant Piping
Connections ................................... 5
i REAR PIPING
i SIDE ORBOTTOM PIPING
i ROUTING THE DRAIN HOSE AND REFRIGERANT
PIPING
i INSTALLING THE INDOOR UNIT BODY TO THE
WALL HANGING BRACKET
i OUTDOOR UNITS
i MAKE PIPING SWEAT CONNECTIONS
i AIR PURGING AND LEAK TEST
Step 4 -- Make Electrical Connections ........... 8
START-UP ....................................... 13
SERVICE ........................................ 14
TROUBLESHOOTING .......................... 14,15
SAFETY CONSIDERATIONS
Installing and servicing air-conditioning equipment can be
hazardous due to system pressure and electrical components.
Only trained and qualified service personnel should install or
service air-conditioning equipment.
Untrained personnel can perform basic maintenance, such
as cleaning and replacing filters. All other operations should be
pertbnned by trained service personnel. When working on air
conditioning equipment, observe safety precautions in litera-
ture, tags, and labels attached to unit.
Follow all safety codes. Wear safety glasses and work
gloves. Use quenching cloth for brazing operations. Have fire
extinmlisher available. Read these instructions thom,Lghly.
Consult local building codes and the National Electrical Code
(NEC) for special installation requirements.
Before installing or servicing system, always turn offmain
power to system. There may be more than one disconnect
switch. Turn off accessory heater power if applicable. Elec-
trical shock can cause serious personal injury.
GENERAL
This system uses R-410A, which Ms higher pressures than
R-22 and other refiigerants. No other refrigerant may be
used in this system. All equipment must be desiNled to
handle R-410A retiigerant. If unsure about equipment, con-
sult the equipment manufacturer.
These instructions cover the installation, start-up and
service of cooling only and heat pump duct-fiee systems.
INSTALLATION
Step 1 -- Complete Pre-lnstallation Checks
UNPACK UNITS (See Fig. 1) 6 Move the unit to final loca-
tion. Relnove unit fiom carton, being careful not to damage
service valves and miltes. See Table 1A tbr installation materi-
als included in shipment and see Table 1B for field-supplied
materials needed to complete the installation.
Fig. 1 -- 40QNC,QNQ Units
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 02-40QN0001-SI Printed in U,S.A. Form 40QN-SSI Pg 1 3-06 Replaces: New