40QNC / 38HDF 40QNQ / 38QRF High---Wall Duct Free Split System Sizes 018 to 036 Product Data INDUSTRY LEADING FEATURES / BENEFITS AN INEXPENSIVE AND CREATIVE SOLUTION TO DESIGN PROBLEMS. The 38HDF(QRF) / 40QNC (QNQ) series duct--free split systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires. The fan coil is mounted on the wall, near the ceiling.
LOW SOUND LEVELS BUILT--IN RELIABILITY When noise is a concern, the duct--free split systems are the answer. The indoor units are whisper quiet. There are no compressors indoors, either in the conditioned space or directly over it, and there is none of the noise usually generated by air being forced through ductwork.
MODEL NUMBER NOMENCLATURE INDOOR UNIT 40 QNC --- 018 3--- 01 Voltage 3 --- 208/230 ---1 ---60 Fan Coil Unit Unit Type QNC --- Cooling Only QNQ --- Heat Pump OUTDOOR UNIT 38 HDF 018 3--- 01 --- Voltage 3 --- 208/230 ---1 ---60 5 --- 208/230 ---3 ---60* 6 --- 460 ---3 ---60* Air ---Cooled Condenser Nominal Capacity 018 --- 1 ---1/2 Tons 024 --- 2 Tons 030 --- 2 ---1/2 Tons 036 --- 3 Tons Unit Type HDF --- Cooling Only QRF --- Heat Pump *Size 036 only ® AHRI* CAPACITY RATINGS Outdoor Section
0QNC,QNQ/38HDF,QRF STANDARD FEATURES AND ACCESSORIES Ease Of Installation Indoor and Outdoor Compact Size Outdoor Unit Wall Mounting Kit Outdoor Unit Stacking Kit Indoor Mounting Bracket Comfort Features Microprocessor Controls Wireless Remote Control Automatic Air Sweep Air Direction Control Auto Restart Function Cold Blow Protection On Heat Pumps Energy Saving Features Sleep Mode Stop/Start Timer Safety And Reliability 3 Minute Time Delay For Compressor Over Current Protection For Compressor Crankcase H
OUTDOOR UNIT ACCESSORIES Low Ambient Kit Stacking Kit The kit controls condenser fan cycling using a pressure switch. It is specifically designed to cycle the outdoor fan--motor in response to saturated condensing pressure. This device maintains a constant saturated condensing temperature of 100 _F ± 10 _F (37.78_C ± 6.5 _C) at outdoor--air temperatures between 55 _F and --20 _F (12.78_C ± --12.22_C), and can be used on all outdoor units without changing the outdoor fan motor.
DIMENSIONS -- INDOOR W D H A08433 W in. (mm) 42.5 (1080) 42.5 (1080) 57.5 (1461) 57.5 (1461) Model Size 40QNC,QNQ/38HDF,QRF 18K 24K 30K 36K H in. (mm) 11.6 (295) 11.6 (295) 13.4 (340) 13.4 (340) D in. (mm) 7.9 (201) 7.9 (201) 9.5 (241) 9.5 (241) Operating Weight lb (kg) 31 31 51 51 (14.1) (14.1) (23.2) (23.2) Fig. 7 – Indoor Dimensions DIMENSIONS - OUTDOOR FEMALE SWEAT CONN.
CLEARANCES -- INDOOR 4 in. (101.6 mm) min. 8 in. (203.2 mm) min. 4 in. (101.6 mm) min. A08357 Fig. 9 – 40QNC,QNQ Indoor Unit Clearance CLEARANCES - OUTDOOR A Air-outlet E D B C Air-inlet A08436 UNIT A B C D E Coil Facing Wall --- in. (mm) 24 (610) 36 (914) 36 (914) 6 (152) 6 (152) Fig. 10 – Outdoor Unit Clearance 7 Fan Facing Wall --- in. (mm) 24 (610) 36 (914) 8 (203) 8 (203) 36 (914) 40QNC,QNQ/38HDF,QRF 80 in (2032 mm) min.
PHYSICAL DATA -- OUTDOOR UNIT 38HDF Outdoor Unit 38HDF System Voltage Nominal Capacity (Btuh) Operating Weight lb(kg) Refrigerant Type Metering Device Piston Size Required Unit Factory Charge lb(kg) System Charge (25 ft line) lb(kg) Additional Charge lb(kg) Compressor 018 208/230 ---1 ---60 18000 166 (75.3) 024 208/230 ---1 ---60 24000 176 (79.8) 030 036 208/230 ---1 ---60 208/230 ---1 ---60 30000 36000 187 (84.8) 250 (113.4) R---410A Accurator at Outdoor Unit 63 70 5(2.3) 8.5(3.9) 49 4.8(2.2) 55 5.
PHYSICAL DATA (CONT.) -- OUTDOOR UNIT 38QRF Outdoor Unit 38QRF System Voltage 018 024 030 036 036 036 208/230 ---1 ---60 208/230 ---1 ---60 208/230 ---1 ---60 208/230 ---1 ---60 208/230 ---3 ---60 460 ---3 ---60 Nominal Capacity (Btuh) 18000 24000 30000 36000 36000 36000 Operating Weight lb(kg) 166 (75.3) 176 (79.8) 187 (84.8) 232 (105.2) 232 (105.2) 232 (105.2) Unit Factory Charge lb(kg) 5.5 (2.5) 6.8 (3.1) 10.7 (4.9) 10.0 (4.5) 10.0 (4.5) 10.0 (4.
PHYSICAL DATA (CONT.) -- INDOOR UNIT 40QNC Indoor Unit 40QNC System Voltage Operating Weight lb(kg) 18/24 18/24 30 36 208/230 ---1 ---60 208/230 ---1 ---60 208/230 ---1 ---60 208/230 ---1 ---60 31 (14.1) 31 (14.1) 51 (23.2) 51 (23.2) Refrigerant Type R---410A Metering Device Accurator At Outdoor Unit Moisture Removal Rate (Pints/hr) 5.4 7.9* 8.
PHYSICAL DATA (CONT.) -- INDOOR UNIT 40QNQ Blower Quantity…Size (in) Indoor Coil Face Area (sq. ft) No.
PERFORMANCE DATA COOLING CAPACITIES 38HDF018 WITH 40QNC01824 Temp ° F (° C) Air Entering Condenser (Edb) 40QNC,QNQ/38HDF,QRF 55 (12.8) 65 (18.3) 75 (23.9) 85 (29.4) 95 (35.0) 105 (40.6) 115 (46.1) 125 (51.7) TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB 460/0.04 57 (13.9) 15.9 14.5 15.7 0.88 0.70 48.8 41.8 15.7 14.8 15.5 1.00 0.81 48.
PERFORMANCE DATA (CONT.) COOLING CAPACITIES 38HDF024 WITH 40QNC1824 55 (12.8) 65 (18.3) 75 (23.9) 85 (29.4) 95 (35.0) 105 (40.6) 115 (46.1) 125 (51.7) TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB 460/0.04 57 (13.9) 20.1 17.5 19.9 1.10 0.91 48.3 40.6 20.3 18.5 20.1 1.25 1.07 46.4 40.4 18.5 16.4 18.3 1.4 1.2 50.4 42.4 18.4 17.6 18.2 1.6 1.
PERFORMANCE DATA (CONT.) COOLING CAPACITIES 38HDF030 WITH 40QNC030 Temp ° F (° C) Air Entering Condenser (Edb) 40QNC,QNQ/38HDF,QRF 55 (12.8) 65 (18.3) 75 (23.9) 85 (29.4) 95 (35.0) 105 (40.6) 115 (46.1) 125 (51.7) TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB 530/0.04 57 (13.9) 26.6 26.0 26.5 1.44 1.25 41.8 39.2 26.4 25.7 26.2 1.63 1.
PERFORMANCE DATA (CONT.) COOLING CAPACITIES 38HDF036 WITH 40QNC036 55 (12.8) 65 (18.3) 75 (23.9) 85 (29.4) 95 (35.0) 105 (40.6) 115 (46.1) 125 (51.7) TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB 600/0.04 57 (13.9) 33.6 31.3 33.4 1.96 1.64 40.0 37.2 32.7 31.2 32.5 2.19 1.87 40.1 37.8 31.6 30.2 31.4 2.44 2.11 41.5 38.6 30.3 29.3 30.1 2.
PERFORMANCE DATA (CONT.) COOLING CAPACITIES 38QRF018 WITH 40QNQ018 Temp ° F (° C) Air Entering Condenser (Edb) 40QNC,QNQ/38HDF,QRF 55 (12.8) 65 (18.3) 75 (23.9) 85 (29.4) 95 (35.0) 105 (40.6) 115 (46.1) 125 (51.7) TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB 460/0.04 57 (13.9) 16.9 15.6 16.6 0.95 0.77 48.9 42.1 16.4 15.5 16.2 1.08 0.
PERFORMANCE DATA (CONT.) COOLING CAPACITIES 38QRF024 WITH 40QNQ024 55 (12.8) 65 (18.3) 75 (23.9) 85 (29.4) 95 (35.0) 105 (40.6) 115 (46.1) 125 (51.7) TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB 460/0.04 57 (13.9) 21.3 19.2 21.1 1.11 0.93 41.8 37.4 19.6 17.4 19.4 1.26 1.08 45.4 39.2 19.1 17.4 18.9 1.42 1.23 45.4 39.8 18.5 17.1 18.2 1.
PERFORMANCE DATA (CONT.) COOLING CAPACITIES 38QRF030 WITH 40QNQ030 Temp ° F (° C) Air Entering Condenser (Edb) 40QNC,QNQ/38HDF,QRF 55 (12.8) 65 (18.3) 75 (23.9) 85 (29.4) 95 (35.0) 105 (40.6) 115 (46.1) 125 (51.7) TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB 530/0.04 57 (13.9) 25.9 25.9 25.7 1.47 1.27 42.0 39.8 26.0 25.5 25.9 1.65 1.
PERFORMANCE DATA (CONT.) COOLING CAPACITIES 38QRF036 WITH 40QNQ036 55 (12.8) 65 (18.3) 75 (23.9) 85 (29.4) 95 (35.0) 105 (40.6) 115 (46.1) 125 (51.7) TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB TCG SHG TC kW CMP LDB LWB 600/0.04 57 (13.9) 31.0 30.0 30.8 1.89 1.56 39.0 37.5 30.2 29.2 30.0 2.11 1.79 40.1 38.0 29.2 28.4 29.0 2.35 2.03 41.1 38.8 28.0 27.4 27.8 2.
65 (18.3) 60 (15.6) 55 (12.8) Air Temperature Entering Indoor Unit ° F (° C) 20 Total Power Input, includes compressor motor power input, outdoor fan motor power input, and indoor fan motor power input kW --- Air Temperature Entering Outdoor Coil ° F (° C) 27 ( --- 2.8) 37 (2.8) Instant. Integrated Instant. Integrated Rating Rating Rating Rating 13.37 11.87 15.53 14.13 1.31 1.42 13.55 12.03 15.73 14.32 1.26 1.35 13.79 12.25 15.97 14.54 1.21 1.28 13.14 11.67 15.27 13.89 1.37 1.46 13.32 11.83 15.50 14.
12.47 12.16 11.97 12.86 12.56 12.37 13.21 12.93 12.74 13.52 13.26 13.08 13.78 13.56 13.40 14.01 13.81 Instant. Rating 13.68 1.84 1.89 1.93 1.76 1.82 1.85 1.68 1.75 1.78 1.61 1.67 1.71 1.54 1.60 1.63 1.48 1.53 1.56 8.66 11.09 10.91 11.72 8.89 8.66 12.04 11.79 11.61 12.33 12.09 11.93 12.57 12.36 12.22 12.77 12.59 Integrated Rating 12.48 13.82 13.57 13.36 14.07 13.84 13.70 14.29 14.09 13.96 14.50 14.31 14.19 14.74 14.51 14.41 14.97 14.
65 (18.3) 60 (15.6) 55 (12.8) Air Temperature Entering Indoor Unit ° F (° C) 22 Total Power Input, includes compressor motor power input, outdoor fan motor power input, and indoor fan motor power input kW --- Air Temperature Entering Outdoor Coil ° F (° C) 27 ( --- 2.8) 37 (2.8) Instant. Integrated Instant. Integrated Rating Rating Rating Rating 20.62 18.31 23.99 21.83 2.11 2.23 20.89 18.55 24.30 22.11 2.03 2.13 21.07 18.71 24.57 22.36 1.96 2.04 20.24 17.98 23.62 21.49 2.23 2.36 20.61 18.30 23.94 21.
34.78 34.26 33.32 35.25 34.74 33.81 35.61 35.20 34.29 36.07 35.55 34.78 36.54 35.99 35.20 37.00 36.46 Instant. Rating 35.71 40QNC,QNQ/38HDF,QRF Total Power Input, includes compressor motor power input, outdoor fan motor power input, and indoor fan motor power input kW --- Air Temperature Entering Outdoor Coil ° F (° C) 27 ( --- 2.8) 37 (2.8) Instant. Integrated Instant. Integrated Rating Rating Rating Rating 26.45 23.49 30.71 27.95 2.89 3.14 27.06 24.04 31.31 28.49 2.73 2.94 27.
APPLICATION DATA UNIT SELECTION SYSTEMS OPERATING CONDITIONS The horizontal units are available as cooling only and heat pumps. For most applications, the cooling load dictates the size selection. Select equipment to either match or be slightly less than anticipated peak load. This provides better humidity control, fewer unit cycles, and better low load performance.
General refrigerant line sizing: 1. Piping for indoor unit can be routed in the direction shown in Fig. 12. A08358A Fig. 12 – Indoor Unit Piping Configurations 2. Refrigerant lines should not be buried in the ground. If it is necessary to bury the lines, not more than 36--in (914 mm) should be buried. Provide a minimum 6--in (152 mm) vertical rise to the service valves to prevent refrigerant migration. 3. Both lines must be insulated. Use a minimum of 1/2--in. (12.7 mm) thick insulation.
SOUND RATINGS Outdoor Units Model Number 38HDF018 --- --- ---3 38HDF024 --- --- ---3 38HDF030 --- --- ---3 38HDF036 --- --- ---3/5/6 38QRF018 --- --- ---3 38QRF024 --- --- ---3 38QRF030 --- --- ---3 38QRF036 --- --- ---3/5/6 Sound Power dBa 66 66 72 72 66 66 72 72 Sound Pressure dBa 55 55 61 61 55 55 61 61 Indoor Units 4QNC,QNQ/38HDF,QRF High Medium Low Model Number Sound Power dBa Sound Pressure dBa Sound Power dBa Sound Pressure dBa Sound Power dBa Sound Pressure dBa 40QNC01824 --- --- ---3
4QNC,QNQ/38HDF,QRF A08367 Fig.
4QNC,QNQ/38HDF,QRF Optional on 38QRF018/024 Models A08368 Fig.
4QNC,QNQ/38HDF,QRF A08369 Fig.
4QNC,QNQ/38HDF,QRF Optional on 38QRF0036 Models Standard on 38QRF030 A08370 Fig.
GUIDE SPECIFICATIONS INDOOR WALL--MOUNTED DUCT--FREE UNITS PART 1 -- GENERAL 1.01 System Description Indoor, wall--mounted, direct--expansion fan coils are matched with cooling only or heat pump outdoor unit . 1.02 Agency Listings Unit shall be rated per ARI Standards 210/240 and listed in the ARI directory as a matched system. Units shall be certified by UL and CSA. 1.03 Delivery, Storage, And Handling Units shall be stored and handled per unit manufacturer’s recommendations. 1.
GUIDE SPECIFICATIONS HORIZ. DISCHARGE OUTDOOR UNITS PART 1 -- GENERAL 1.01 System Description A. Outdoor air--cooled split system compressor sections suitable for on--the--ground, rooftop, wall hung or balcony mounting. Units shall consist of a scroll compressor, an air--cooled coil, propeller--type blow--through outdoor fan, reversing valve (HP), accumulator, Accurator metering device(s), and control box. Units shall discharge air horizontally as shown on the contract drawings.
NOTES: ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ __________________________________________________________________
4QNC,QNQ/38HDF,QRF Copyright 2008 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 12/08 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 34 Catalog No.