Spec Sheet
Table Of Contents
38MHRC-01PD Specifications subject to change without notice. 17
Air Flow Data
Sound Data
Sound Pressure In Octave Bands
Outdoor Unit Sound Pressure Test Conditions
Fig. 7 — Outdoor Unit Sound Pressure Test Conditions
38MHRCQ UNIT SIZE 12K (115V) 9K (208/230V) 12K (208/230V) 18K (208/230V) 24K (208/230V)
Outdoor (CFM) 1,235 1,294 1,235 1,235 1,765
38MHRCQ UNIT SIZE (HP) 12K (115V) 9K (208/230V) 12K (208/230V) 18K (208/230V) 24K (208/230V)
Outdoor Sound Pressure Level dB(A)
53.5 55 55.5 55 59.5
Outdoor Sound Power Level dB(A) 63.1 64.2 64.5 64.3 69.7
Frequency (Hz) 63 125 250 500 1000 2000 4000 8000
12 K (115V)
Cooling dB 57.6 50.0 54.4 49.6 45.6 40.0 35.6 35.3
Heating dB 59.8 52.1 55.1 49.2 47.7 42.5 37.4 31.6
Indoor dB 38.8 34.4 38.3 38.6 37.8 33.1 23.1 14.4
9K (208V)
Cooling dB 53.3 58.8 57.2 51.2 48.5 42.0 36.1 31.2
Heating dB 55.5 58.4 56.6 51.0 48.0 41.8 36.1 31.3
Indoor dB 38.1 33.6 38.5 37.9 36.2 29.6 20.6 13.6
12K (208V)
Cooling dB 57.8 58.2 53.9 49.2 46.0 40.5 37.0 32.8
Heating dB 60.0 57.9 58.4 52.9 47.5 44.2 41.2 36.7
Indoor dB 34.4 32.2 37.5 39.4 37.8 31.9 22.5 14.9
18K (208V)
Cooling dB 60.9 56.5 54.2 51.0 46.5 41.5 37.0 33.6
Heating dB 62.5 55.9 52.8 53.9 47.9 44.0 39.4 36.1
Indoor dB 37.8 36.5 40.6 40.7 40.0 34.9 27.5 17.1
24K (208V)
Cooling dB 56.8 60.5 60.1 54.5 50.5 45.7 39.8 34.5
Heating dB 60.4 59.9 62.7 56.5 52.2 47.2 42.5 39.3
Indoor dB 39.0 38.7 45.0 43.7 45.5 39.5 33.0 24.4