Brochure

Included Optional
Heat Pump with factory installed base pan heater – Variable Speed System
MA*R Series Ceiling Cassette Single Zone Heat Pump with Inverter Technology
Outdoor Unit
208/230V
Indoor Unit
208/230V requires
40MBQB01C--- ceiling
grille
Rated
Cooling
Btuh
Rated
Heating
Btuh
SEER
EER
HSPF
Heating Capacity BTU's / % of rated
Indoor unit is powered from outdoor unit.
Outdoor Unit
208/230V
Indoor Unit
208/230V requires
40MBQB01C--- ceiling
grille
Rated
Cooling
Btuh
Rated
Heating
Btuh
SEER
EER
HSPF
Indoor Conditions DB 69°F
Indoor unit ceiling grille required and SOLD SEPARATELY p/n: 40MBQB01C---
20.0
16,000
18,000
40MBQB18C--3
40MBQB12C--3
Heating Capacity BTU's / % of rated
At 5°F
Outdoor
Ambient
At -13°F
Outdoor
Ambient
At -22°F
Outdoor
Ambient
40MBQB09C--3
13.0
20.0
9,000
9,000
40MBCQ09---3
40MBCQ12---3
40MBCQ18---3
7,540 / 63%
6,890 / 57%
7,160 / 80%
7,320 / 81%
10,472 / 116%
KSACN0501AAA
Programmable Wired Wall Mount Controller
Includes 19ft cable / max 66ft
17317100A11945
Programmable Cooling Only Wired Controller
Includes 19ft cable / max 66ft
Indoor unit includes integrated condensate lift pump. Drain line connection 25mm or 0.98" outside diameter.
Carrier Duct-Free System Accessories Compatible With 40MBQBxxC--3 Cassette IDU's
Accessory Model
Description
Notes
KSACN0101AAA
Non-Programmable Wired Wall Mount Controller
Includes 19ft cable / max 66ft
17401204001601
19ft Extension Cable Kit for KSCAN0101AAA
Sold separately through RCD
Misc. Operational Data
9,000
12,000
18,000
Cooling Cap. Range; Min-Max Btu/h
3,500 - 11,000
4,000 - 13,000
4,500 - 18,000
17401204000769
17317100A33862
Cooling Only Wireless Remote Control
Non-Programmable
19ft Extension Cable Kit for KSCAN0501AAA & 17317100A11945 (through RCD)
Heating Outdoor DB Min - Max °F
Outdoor Ambient -22°F to 86°F
Maximum Line Set Length
82 Feet
82 Feet
98 Feet
Heating Cap. Range; Min-Max Btu/h
4,500 - 11,500
5,000 - 13,500
5,500 - 19,000
Cooling Outdoor DB Min - Max °F
Outdoor Ambient -13°F to 122°F
Precharged for 25ft of line set
Weigh In 0.16oz/ft >25ft
ODU Precharged R410a
3.31 lbs
3.31 lbs
4.30 lbs
Maximum Elevation / Lift
32 Feet
32 Feet
65 Feet
Minimum Line Set Length
10 Feet
10 Feet
10 Feet
25A
Liquid Line Connection Size
1/4"
1/4"
1/4"
Suction/Vapor Line Connection Size
3/8"
1/2"
1/2"
10.8
12,000
12,000
19.5
12.5
10.6
12,220 / 102%
Controller Set Point Range
62°F to 86° Applicable to Heating Mode and Cooling Mode; Wired or Wireless Controllers
38MAQB09R--3
38MAQB12R--3
38MAQB18R--3
11,910 / 74%
12,589 / 79%
19,005 / 119%
10.5
12.5
Minimum Circuit Ampacity
9A
9A
18A
Maximum Over-Current Protection
15A
15A