20
WIRING DIAGRAMS
Fig. 6 – Wiring Diagram Sizes 09K−12K (115V)
CODE PART NAME CODE PART NAME
CN1A
INPUT:115V High voltage connector with
L/N/Ground/Signal
CN60 Output:115 VAC for 4-way valve control
CN4_1 CN4_2
CN4_3 CN4 4
Output: 115VAC High voltage connector for
power factor corrector (PFC)
CN50
Output: PWM for UVW to control
Compressor(0-320VAC)
CN7
Output: PWM for UVW to control the
outdoor fan (0-320VAC)
CN21 Input: Temperature acquisition (0-5VDC)
CN15
Output:1 15VAC High voltage to control
base pan heater
CN31
Connector for electronic expansion
valve (0-12VDC)
CN17
Output:1 15VAC High voltage to control
crankcase heater