Specification Sheet

16
COOLING PERFORMANCE DATA FLOOR CONSOLE
MODEL
COOLING OUTDOOR CONDITIONS (DB)
Indoor Conditions
DB
77F
(25C)
86F
(30C)
95F
(35C)
104F
(40C)
113F
(45C)
122F
(50C)
DB WB
09
(208-230V)
69.8F
(21C)
59F
(15C)
TC 8.47 8.26 7.79 6.49 6.04 5.53
SC 6.35 6.28 6.00 5.39 4.89 4.70
Input 0.68 0.88 1.15 1.00 0.93 0.91
75.2F
(24C)
62.6F
(17C)
TC 9.56 9.06 8.33 7.12 6.75 6.12
SC 7.45 6.88 6.50 5.77 5.47 5.20
Input 0.70 0.89 1.16 1.01 0.97 0.93
80.6F
(27C)
66.2F
(19C)
TC 10.59 9.90 9.30 7.78 7.32 6.86
SC 6.25 7.03 6.51 5.91 5.93 5.76
Input 0.70 0.91 1.18 1.02 1.00 0.96
89.6F
(32C)
73.4F
(23C)
TC 11.87 11.02 10.11 8.56 8.02 7.66
SC 8.42 7.83 7.38 6.42 6.10 6.13
Input 0.73 0.95 1.22 1.08 1.01 0.99
12
(208-230V)
69.8F
(21C)
59F
(15C)
TC 8.47 8.26 7.79 6.49 6.04 5.53
SC 6.35 6.28 6.00 5.39 4.89 4.70
Input 0.68 0.88 1.15 1.00 0.93 0.91
75.2F
(24C)
62.6F
(17C)
TC 9.56 9.06 8.33 7.12 6.75 6.12
SC 7.45 6.88 6.50 5.77 5.47 5.20
Input 0.70 0.89 1.16 1.01 0.97 0.93
80.6F
(27C)
66.2F
(19C)
TC 10.59 9.90 9.30 7.78 7.32 6.86
SC 6.25 7.03 6.51 5.91 5.93 5.76
Input 0.70 0.91 1.18 1.02 1.00 0.96
89.6F
(32C)
73.4F
(23C)
TC 11.87 11.02 10.11 8.56 8.02 7.66
SC 8.42 7.83 7.38 6.42 6.10 6.13
Input 0.73 0.95 1.22 1.08 1.01 0.99
LEGEND
DB - Dry Bulb
WB - Wet Bulb
TC - Total Net Capacity (1000 Btu/hour)
SC - Sensible Capacity (1000 Btu/hour)
Input - Total Power (kW)
HEATING PERFORMANCE DATA FLOOR CONSOLE
MODEL HEATING OUTDOOR CONDITIONS (DB)
Indoor Conditions
DB
-13F
(-25C)
-4F
(-20C)
0F
(-17C)
5F
(-15C)
17F
(-8C)
19.4F
(-7C)
24.8F
(-4C)
32F
(0C)
39.2F
(4C)
44.6F
(7C)
53.6F
(12C)
09
(208-230V)
59F
(15C)
TC 8.13 8.67 9.36 10.42 12.64 12.89 13.25 13.68 13.97 14.30 16.03
Input 1.72 1.75 1.87 1.86 1.86 1.79 1.60 1.45 1.43 1.42 1.38
COP 1.39 1.45 1.47 1.64 2.00 2.11 2.42 2.77 2.86 2.95 3.40
64.4F
(18C)
TC 8.02 8.57 9.18 10.19 12.13 12.38 12.67 13.05 13.76 14.39 15.32
Input 1.77 1.81 1.89 1.91 1.96 1.77 1.62 1.48 1.47 1.44 1.47
COP 1.33 1.39 1.43 1.56 1.82 2.05 2.30 2.59 2.75 2.92 3.07
69F
(20.5C)
TC 7.95 8.41 9.02 9.99 11.54 11.77 12.13 12.45 13.55 14.45 14.25
Input 1.81 1.84 1.90 1.97 2.01 1.98 1.62 1.51 1.49 1.46 1.54
COP 1.29 1.34 1.39 1.49 1.68 1.74 2.20 2.42 2.67 2.90 2.71
71.6F
(22C)
TC 7.85 8.37 9.00 9.59 11.14 11.36 11.77 12.06 13.36 14.19 13.62
Input 1.85 1.87 1.95 1.99 2.10 2.07 1.66 1.56 1.50 1.48 1.50
COP 1.25 1.31 1.35 1.41 1.56 1.61 2.08 2.27 2.61 2.81 2.67
12
(208-230V)
59F
(15C)
TC 8.34 8.88 9.60 10.68 12.96 13.21 13.59 14.02 14.32 14.66 16.43
Input 1.76 1.79 1.91 1.91 1.90 1.83 1.64 1.48 1.47 1.46 1.41
COP 1.39 1.45 1.47 1.64 2.00 2.11 2.42 2.77 2.86 2.95 3.40
64.4F
(18C)
TC 8.22 8.78 9.41 10.44 12.44 12.69 12.98 13.38 14.11 14.75 15.71
Input 1.81 1.86 1.93 1.96 2.01 1.81 1.66 1.51 1.50 1.48 1.50
COP 1.33 1.39 1.43 1.56 1.82 2.05 2.30 2.59 2.75 2.92 3.07
69F
(20.5C)
TC 8.15 8.62 9.25 12.01 11.83 12.06 12.44 12.76 13.89 14.81 14.61
Input 1.86 1.89 1.94 2.00 2.06 2.03 1.66 1.55 1.52 1.50 1.58
COP 1.29 1.34 1.39 1.76 1.68 1.74 2.20 2.42 2.67 2.90 2.71
71.6F
(22C)
TC 8.05 8.58 9.22 9.83 11.41 11.64 12.06 12.36 13.70 14.54 13.96
Input 1.89 1.91 1.99 2.04 2.15 2.12 1.70 1.59 1.54 1.52 1.54
COP 1.25 1.31 1.35 1.41 1.56 1.61 2.08 2.27 2.61 2.81 2.67
LEGEND
DB - Dry Bulb
TC - Total Net Capacity (1000 Btu/hour)
Input - Total Power (kW)