Installation guide

If
you
have
two
units
installed
in
the
same
space
and
they
need
to
work
independently,
the
remote
controls
and
the
units
need
to
be
configured
as
follows:
Unit
Configuration
Turn
the
unit
off
by
pressing
the
O}
Press
and
hold
the
M
and
A
buttons
of
the
remote
control
for
more
than
5
seconds.
The
display
will
be
cleared
and
the
time
segments
will
display
the
first
configuration
item
(rAdr=remote
address)
and
the
temperature
segments
will
display
the
default
value
of
this
configuration
item
(Ab=control
of
both
indoor
units).
Press
A
and
V
to
change
the
oN
default
value
to
the
new
value
of
(a)
or
(b).
Press
the
“/1
button
to
transmit
the
new
configuration
to
the
unit.
Press
the
®
button
to
leave
the
configuration
menu.
Remote
Control
Configuration
Turn
the
unit
off
by
pressing
the
®
button.
Press
and
hold
the
V
and
A
buttons
for
more
than
5
seconds.
The
display
will
be
cleared
and
the
time
segments
will
display
the
first
configuration
item
(CH=remote
address)
and
the
temperature
segments
will
display
the
default
value
of
this
configuration
item
(Ab=control
of
both
indoor
units).
Press
A
and
V
to
change
the
default
value
to
the
new
value
of
(a)
oN
or
(b).
Press
the
“/I
button
to
transmit
the
new
configuration
to
the
unit.
Press
the
®
button
to
leave
the
configuration
menu.
NOTE:
When
30
seconds
have
elapsed
and
no
buttons
have
been
pressed,
the
remote
control
will
automatically
exit
the
configuration
menu
and
resume
its
normal
operation.
A
wall
mounted
control
or
zone
manager
can
be
used
to
control
a
unit
or
multiple
units.
Zone
Manager
If
a
Zone
Manager
is
required,
the
following
steps
should
be
performed
at
the
same
time
the
indoor
control
and
power
wiring
are
being
connected:
a.
Remove
the
cover
of
the
Internal
Control
Panel
to
get
access
to
the
microprocessor
board.
See
Fig.
33.
b.
Plug
the
communication
board
to
the
J8
as
shown
in
Fig.
34.
c.
Connect
one end
of
the
wire
harness
supplied
with
the
Zone
Manager
to
the
communication
board.
d.
Route
the
other
end
of
the
wire
harness
along
the
voltage
control
to
the
back
of
the
unit.
e.
Connect
the
other
end
of
the
wire
harness
to
the
field
supplied
wiring
that
will
be
connected
to
the
zone
man-
ager
as
shown
in
Fig.
34
(shielded
cables
are
required.
Refer
to
Zone
Manager
Installation
Instructions).
f.
Reinstall
the
cover
of
the
internal
control
panel.
@
Main
board
@
Communication
board
(supplied
with
the
kit)
@
5-cable
wiring
(supplied
with
the
kit)
@
Auxillary
terminal
block
(supplied
with
the
kit)
©)
Wiring
by
the
installer
@
Zone
Manager
terminal
block
(mounted
on
the
Zone
Manager)
@
Indoor
unit
Seer
@
®
WHITE
A
c
®
H—
—S-|-
71
GREY
9-9]
pak,
8
@
BLUE
e-—el4—1,
|
neo
lh
tata
__]
BLACK
GND
!
i
i |
\
/1989908e
A
®
T
=
©
;
|LLT
TTT
Pe
meee
ce
cme
moe
ph
ma
<0
o>
@
4
22
A09514
Fig.
34
-
Wiring
for
Zone
Manager