40GVC / 38GVC 40GVQ / 38GVQ High---Wall Ductless Split Systems Size 009K --- 036K Product Data INDUSTRY LEADING FEATURES / BENEFITS AN INEXPENSIVE AND CREATIVE SOLUTION TO DESIGN PROBLEMS. The 38GVC(Q)/40GVC(Q) inverter driven ductless split systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires. The fan coil is mounted on the wall, near the ceiling.
38/40GVC(Q) INVERTER TECHNOLOGY - COMFORT FAST INSTALLATION The inverter driven compressor is designed to run at various input power frequencies (Hz) which controls the motor speed of the compressor. Even Temperature – The control package, including the inverter, monitors outdoor and indoor temperatures as they relate to the selected indoor set point and adjusts the speed of the compressor to match the load and keep the system operating continuously rather than cycling and creating temperature swings.
MODEL NUMBER NOMENCLATURE INDOOR UNIT 40 GVQ 009 --- --- --- 1 Voltage 1 --- 115 ---1 ---60 3 --- 208/230 ---1 ---60 Fan Coil Unit Unit Type GVC --- Cooling Only GVQ --- Heat Pump 38/40GVC(Q) Nominal Capacity 009 --- 3/4 Ton 012 --- 1 Ton 018 --- 1 ---1/2 Ton 024 --- 2 Ton 030 --- 2 ---1/2 Ton (HP only) 036 --- 3 Ton OUTDOOR UNIT 38 GVQ 009 --- --- --- Air ---Cooled Condenser Nominal Capacity 009 --- 3/4 Ton 012 --- 1 Ton 018 --- 1 ---1/2 Ton 024 --- 2 Ton 030 --- 2 ---1/2 Ton (HP only) 036 --
38/40GVC(Q) STANDARD FEATURES AND ACCESSORIES Ease Of Installation Mounting Brackets Low Voltage Controls Comfort Features Microprocessor Controls Wireless Remote Control Rapid Cooling/Heating Automatic Air Sweep Cold Blow Prevention Continuous Fan * Auto Restart Feature Memory Function Auto Changeover on Heat Pumps Dry Function Energy Saving Features Inverter Driven Compressor Sleep Mode 24 Hour Stop/Start Timer Safety And Reliability Indoor Unit Freeze Protection 3 Minute Compressor Time Delay High Compr
DIMENSIONS -- INDOOR W D H A12377 9K 12 K 18 K 24 K 30/36 K H In. (mm) 11.1 (283) 11.1 (283) 12.0 (305) 12.6 (319) 12.8 (325) D In. (mm) 7.9 (201) 7.9 (201) 8.5 (215) 8.7 (221) 10.0 (254) Net Operating Weight Lbs. (Kg) 18.7 (8.5) 19.8 (9.0) 26.4 (12) 33.1 (15.0) 44.1 (20.0) 38/40GVC(Q) Unit Size W In. (mm) 30.3 (770) 30.3 (770) 34.0 (865) 39.7 (1008) 53.1 (1349) Fig. 2 – Indoor Unit Dimensions DIMENSIONS - OUTDOOR 10.1 (257) 21.3 (540) 30.0 (762) 12.6 (320) 33.4 (848) 11.7 (267) Unit: IN.
DIMENSIONS - OUTDOOR CONTINUED 25.9 (658) 38/40GVC(Q) 21.7 (551) 10.8 (274) 28.0 (711) 12.5 (318) 18.5 (470) Unit: IN. (mm) 11.8 (300) Unit: IN. (mm) A12532 Fig. 4 – 12K 230V (Net Operating Weight: 63.8 lbs. / 30 kg) 35.0 (890) 27.6 (700) 13.4 (340) 37.9 (963) 15.6 (396) 22.0 (560) 14.3 (364) Unit: IN. (mm) A12533 Fig. 5 – 18K and 24K (Net Operating Weight: 112.2 lbs.
DIMENSIONS - OUTDOOR CONTINUED 36 (914.4) 14.6 (370.8) 38/40GVC(Q) 31.1 (789.9) 16.7 (424.2) 38.6 (980.4) 24 (609.6) 15.7 (398.8) in. (mm) A12379 Fig. 6 – 30K and 36K (Net Operating Weight: 30K = 154 lbs. / 70 kg; 36K = 161 lbs.
CLEARANCES Indoor Unit Distance to Ceiling 6 in (152 mm) Distance to Wall 6 in (152 mm) 38/40GVC(Q) Distance to Wall 6 in (152 mm) Distance in Front of Unit 118 in (2997 mm) Distance to Floor 66 in (1676 mm) NOTE: Refrigerant lines may be routed in any of the (4) directions, right, right rear, left, or left rear. See instructions for details ● The clearance dimensions are necessary for a correct installation and are the minimum permissible distances to adjacent structures.
PHYSICAL DATA -- 38GVC Outdoor Unit 38GVC 009 System Voltage 012 012 Cooling. Capacity Range Min --- Max (Btuh) 036 Low Voltage Pulse DC 9,000 11,800 12,000 18,000 22,000 33,600 3,500 --- 11,000 3,300 --- 12,500 3,300 --- 12,500 4,500 --- 21,000 6,400 --- 24,000 7,400 --- 36,000 Operating Weight lb. (kg) 75 (34) 63.8 (30) Refrigerant Type 112.2 (51) 161 (73) R---410A Metering Device @ Outdoor Unit Charge lb.
PHYSICAL DATA CONTINUED -- 40GVC Indoor Unit 40GVC 009 System Voltage 012 012 036 Low Voltage Pulse DC Electrical Connections Operating Weight lb. (kg) 024 208/230 ---1 ---60 Control Voltage Rated Cooling Capacity (Btuh) 018 115 V Indoor Unit Powered From Outdoor Unit 9,000 11,800 18.7 (8.5) 12,000 19.8 (9.0) Refrigerant Type 18,000 22,000 33,600 26.5 (12.0) 33.1 (15.0) 44.1 (20) R---410A Metering Device @ Outdoor Unit EXV Cap. Tube 1.7 2.9 2.9 3.8 4.5 7.
PHYSICAL DATA CONTINUED -- 38GVQ Outdoor Unit 38GVQ 009 012 System Voltage 012 018 024 115--- 1--- 60 030 036 208/230--- 1--- 60 Control Voltage Low Voltage Pulse DC Rated Cooling Capacity (Btuh) 9,000 11,800 12,000 18,000 22,000 28,000 33,600 Cooling.
PHYSICAL DATA CONTINUED -- 40GVQ Indoor Unit 40GVQ 009 System Voltage 012 012 018 024 115 V 030 036 33,600 208/230--- 1--- 60 Control Voltage Low Voltage Pulse DC Electrical Connections Indoor Unit Powered From Outdoor Unit Rated Cooling Capacity (Btuh) 9,000 11,800 12,000 18,000 22,000 28,000 Rated Heating Capacity (Btuh) 10,000 13,000 12,000 19,200 26,600 30,600 26.5 (12.0) 33.1 (15.0) Operating Weight lb (kg) 18.7 (8.5) 19.8 (9.
UNIT MOUNTING (INDOOR) REFRIGERANT LINES Mounting template – The fan coil units are furnished with mounting bracket to hang the unit and mark the location of the wiring, and refrigeration line hole locations. Support – Adequate support must be provided to handle the weight of all fan coils. Refer to the Physical Data section for weights, and the base unit dimensional drawings for the location of mounting bracket. Unit Leveling – For reliable operation, units should be level in all planes.
DRAIN CONNECTIONS Install drains to meet the local sanitation codes. If adequate gravity drainage cannot be provided, a field installed condensate pump accessory should be used. For pump lift capability, please refer to the Installation Instructions for the condensate pump accessory (53DS--900------117 for 115v / 53DS--900------118 for 230v). NOTE: The high wall fan coils have internal condensate trap. An external trap is not required.
AIR THROW DATA Unit Size Approximate Air Throw ft. (m) Medium High 21 (6.4) 23 (7.0) 23 (7.0) 25 (7.6) 27 (8.2) 33 (10.1) 29 (8.8) 34 (10.4) 37 (14.3) 40 (12.1) 40 (12.1) 45 (13.7) Low 18 (5.5) 20 (6.1) 22 (6.7) 25 (7.6) 35 (10.7) 37 (11.3) 9K 12 K 18 K 24 K 30 K 36 K Turbo 28 (8.5) 30 (9.1) 39 (11.9) 42 (12.
GUIDE SPECIFICATIONS HORIZONTAL DISCHARGE OUTDOOR UNITS Size Range: 3/4 -- 3 Ton Nominal Cooling and Heating Capacity Carrier Model Number: 38GVC(Q) PART 1 – GENERAL 38/40GVC(Q) 1.01 System Description A. Outdoor air-cooled split system compressor sections suitable for on-the-ground, rooftop, wall hung or balcony mounting. Units shall consist of a variable speed rotary compressor, an air-cooled coil, propeller-type draw-through outdoor fan, reversing valve, accumulator, metering devices, and control box.
GUIDE SPECIFICATIONS INDOOR WALL--MOUNTED DUCT--FREE UNITS Size Range: 3/4 -- 3 Ton Nominal Cooling and Heating Capacity Carrier Model Number: 40GVC(Q) 1.01 System Description Indoor, wall-mounted, direct expansion fan coils are matched with heat pump outdoor units. 1.02 Agency Listings Unit shall be rated per ARI Standards 210/240 and listed in the ARI directory as a matched system. Units shall be evaluated in accordance with UL standard 1995. Units shall be listed in CEC directory. 1.
38/40GVC(Q) Copyright 2013 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Edition Date:01/13 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 18 Catalog No.