Manual

NOTE:Whenchargingis necessaw-duringheatingseason,
chargemustbeweighedinaccordancewithunitratingplate÷0.6
oziftof3/8-in.liquidlineaboveorbelow15ftrespectively.
EXAMPLE:
Tocalculateadditionalchargerequiredfora25 ft line set:
25 fi 15 ft 10 ft X 0.6 ozit't 6 oz of additional charge
Step 15--Final Checks
mNPORTANT: Before leaving job, be sure to do the fbltowing:
1. Securely fitsten all panels and covers.
2. Tighten service valve=stem caps to 1i12=mm past finger-tight.
3. Leave L ser's Manual with owner Explain system operation
and periodic maintenance requirements outlined in manual.
4. Fill out Dealer Installation Checklist and place in customer
file.
CARE AND MAINTENANCE
For continuing high per%m_ance and to minimize possible equip=
ment failure, periodic maintenance must be perfbm_ed on this
equipment
Frequency of maintenance may vary depending upon geographic
areas, such as coastal applications
Copyright 2002 CARRIER Corp. _ 7310 W. Morris St Indianapolis. IN 46231 38byc3si
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
B°°k 1h_ PC 101 catalog No. 533-80078 Printed in USA Form 38BYC-3SI Pg 8 11-02 Replaces: 38BYC-2SI
Tab 15al 5a