5 Diagnostic interface
The diagnostic interface can be used for
configuration download,
diagnostic purposes and
firmware update (firmware update at netRAPID NRP 10 only)
It is mandatory to add a diagnostic interface to the host system.
This interface is needed during the production process to load the Second Stage Boot Loader and
firmware into the netRAPID device.
5.1 USB interface
The USB interface is needed during production to load the Second Stage Boot Loader and the
firmware into the netRAPID device. The USB interface is handled by the ROM loader in this case.
Once the Second Stage Boot Loader is running, the Second Stage Boot Loader handles the USB
interface.
Once the firmware is running, the firmware handles the USB interface.
Note: The standard firmware activates the USB interface by default.
The following pins of the netRAPID relate to the Universal Serial Bus (USB) interface.
Pin Name
44 USB-
45 USB+
Table 9: Pin assignment of USB interface
The USB signals have LVTTL level (3.3 V).
Note: USB is used for diagnostic and for production purposes.
Note: The external USB power supply line is not used by the netRAPID.
The USB signals have to be protected with 22 and transient diode. The circuit for the host
system is shown in chapter Schematics which is on page 62 (NRPEB-CCS and NRPEB-DPS) or
page 64 (NRPEB-RE2).