Installation guide
TheOutdoorCoilTemperature(OCT)Thermistoris factory
installedonthe3/8"diameterstubtubelocatedonthecoil
assembly.Checktomakesurethatitissecurelyattachedwiththe
clipasshowninFig.8.
OCT Thermistor
must be secured
tight on stub tube,
A05409
Fig. 8 - Outdoor Coil Thermistor (OCT) Attachment
START-UP
UNIT OPERATION AND SAFETY HAZARD
Failure to follow this caution may result in minor personal
injury, equipment damage or improper operation.
To prevent compressor damage or personal injury,
observe the following:
• Do not overcharge system with refrigerant.
• Do not operate unit in a vacuum or at negative pressure.
• Do not disable low pressure switch in scroll compressor
applications.
• Dome temperatures may be hot.
PERSONAL INJURY HAZARD
Failure to follow this caution may result in personal injury.
Wear safety glasses, protective clothing, and gloves when
handling refrigerant and observe the following:
• Back seating service valves are not equipped with Schrader
valves. Fully back seat (counter clockwise? valve stem
before removing gage port cap.
ENVIRONMENTAL HAZARD
Failure to follow this caution may result m environmental
damage.
Federal regulations require that you do not vent refrigerant to
the atmosphere. Recover during system repair or final unit
disposal.
Follow these steps to properly start up system:
1. After system is evacuated, fully open liquid and vapor ser-
vice valves.
2. Unit is shipped with valve stem(s) closed and caps in-
stalled. Replace stem caps after system is opened to refri-
gerant flow (back seated). Replace caps finger-tight and
tighten with wrench an additional 1/12 turn.
3. Close electrical disconnects to energize system.
4. Set room thermostat at desired temperature. Be sure set
point is below indoor ambient temperature.
5. Set room thermostat to HEAT or COOL and fan control to
ON or AUTO mode, as desired. Operate unit for 15
minutes. Check system refrigerant charge.
Variable-Speed
Furnace / Fan Coil
Userlntefface
EB
EB
EB
EB
G_eel_
Yeiiow
White
Red
_ Op/ional Remote
Room Sensor
Humidifier
Connection
ED
rTh
----O
{UM
---O
COM
®
OAT
®
Green
Yeiiow
White
Red
ABCD
Connection
Fig. 9 - Infinity Control Four-Wire
Connection Diagram
Single Speed HP
A06078
NOTE: Wiring must conform to NEC or local codes.
NOTE: For standard thermidistat or thermostat wiring, see
Installation Instructions for those products.
TYPICAL HEAT
HP THERMOSTAT FAN COIL PUMP
24 MAC HOT D
24 MAC COM
HEAT STAGE 2
COOL/HEAT
STAGE 1
INDOOR FAN
RVS COOLING E_
EMERGENCY D
HEAT
* tF AVAILABLE
LEGEND
24V FACTORY WIRING
24V FIELD WIRING
FIELD SPLICE CONNECTION
_P OUTDOOR THERMOSTAT
@ EMERGENCY HEAT RELAY
@ SUPPLEMENTAL HEAT RELAY
A02325 A97413
Fig. 10 - Generic Wiring Diagram for Standard
Thermostat Installations