Technical data
Installation and Service Guide N5250-90001 3-21
PNA Series Microwave Network Analyzer System System Installation
N5250A Disconnecting the Combiner Assembly From the mm-Wave Module
Figure 3-12 New Design Combiner Assembly and mm-Wave Module: View 3
4. Remove the four waveguide screws (item 1).
5. Remove the four screws (item 2).
6. Reverse the process to reassemble.
NOTE Do NOT switch modules. Combiner must be reassembled to the mm-wave module in which it
was originally installed.
7. Perform an Operator’s Check after reassembly to test for power holes, etc.
1
2
(4 places)
(4 places)
N5230_013_318