User manual

Axxius 800 - Release 2.2 51
Quick Start
Provision a Unit
Establish a Static Channel Connection
Use the following commands to establish a static channel connection.
Set Up a V.35 Port
Use the following commands to set up a V.35 port.
Command Description
set {ds0-addr} type
{voice|data}
Set the channel type for the channel you
want to map. See set (ds0) command for
details.
set {ds0-addr} signal {emdw|
emi|emicpd|emw|gs|ls}
Set the signaling option for the channel you
want to map. See set (ds0) command for
details.
connect {slot:port}
{slot:port}
Connect the channels. See the show connect
command for details.
Command Description
set {v35-addr} cts
{cd|high|low|rts}
Set the Clear to Send operation mode. See
set (v35) command for details.
set {v35-addr} data
{invert|normal}
Set the data mode. See set (v35) command
for details.
set {v35-addr} clock
{source|external}
Set the clock mode. See set (v35) command
for details.
set {v35-addr} speed
{56K|64K}
Set the speed. See set (v35) command for
details.
set {v35-addr} txclkinv
{invert|normal}
Set the transmit clock inversion mode. See
set (v35) command for details.
set {v35-addr} rxclkinv
{invert|normal}
Set the receive clock inversion mode. See
set (v35) command for details.