User manual
Axxius 800 - Release 2.2 45
Quick Start
Provision a Unit
Provision a Unit
l Local using CLI, Telnet, Modem or SNMP (Valet)
l Remotely over an in-band DS0
l Remotely over an SNMP network using NetworkValet EMS
Command Line Interface (CLI)
You can access the CLI using either of the following methods:
l RS-232 connected to the DB-9 port.
l Telnet via Ethernet (10Base-T)
l Modem
Setting up a CLI connection
To connect to the CLI via the RS-232 port, set up a connection to a PC serial port
or dumb terminal using Hyperterm, ProComm, or similar terminal emulation
software:
l Set the Port Settings to:
Bits per second: 9600
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
l Set the Terminal Emulation to: VT100
NOTE: The Default IP address of the Axxius 800 Controller is 10.0.0.10.