Axxius 800 User Manual

Table Of Contents
7-6 Axxius 800 - Release 2.2
DS3 Controller Card
Technical Specifications
Testing and Diagnostics
l Supports maintenance signals specified in ANSI T1.404 (Section 7.1)
l Standard DS3 line and payload loopbacks
l RFC 2496 performance history
Power Consumption
l 10 W maximum
Environment
In addition to the systems environment requirements, the following applies to the DS3
Controller card. For additional information see Installation Environment on page 2-3.
l Operating temperature range of the DS3 Controller card: -40° to 149° F
(-40° to 65° C)
Physical
l Dimensions: 3.5 in. (H) x 0.75 in. (W) x 11.25 in. (D)
8.9 cm (H) x 1.9 cm (W) x 28.6 cm (D)
l Weight: 10.2 oz. (0.29 kg)