Operating instructions

Rexroth IndraDrive Mounting and Installation 6-3
DOK-INDRV*-FU*********-IB01-EN-P
Distances for Drive Controllers
In addition to the mounting dimensions, the components of the
Rexroth IndraDrive range require additional mounting clearance
to ventilate the components
to mount accessories and connections
to take temperature limits of neighboring mounting parts, such as
cable ducts etc., into account
To determine the required mounting clearances in the control cabinet,
take additional distances between the components and on their tops and
bottoms into account.
Distance between Drive Controllers
Owing to power dissipation in the components, especially due to installed
braking resistors in compact devices, the temperatures of neighboring
components are rising. In the case of lateral mounting, trouble-free
operation therefore requires the following minimum distances in [mm]
between the components.
tofrom
HCS02 HCS03 (HNK01,
HLR01)
HCS02.1E 5 --
HCS03.1E with HNK01 and HLR01 -- 0
-- not allowed
Fig. 6-4: Minimum distance in [mm]