Operating instructions

Rexroth IndraDrive Mounting and Installation 6-1
DOK-INDRV*-FU*********-IB01-EN-P
6 Mounting and Installation
6.1 Mounting
Dimensions – Power Sections
Device Depths, Heights and Widths
Device Device
width
[mm]
Min.
moun-
ting
width
[mm] 1)
Device
height
[mm] 2)
Device depth
[mm] 3)
HCS02.1E-W0012 65 70 290
HCS02.1E-W0028 65 70 352
HCS02.1E-W0054 105 110 352
HCS02.1E-W0070 105 110 352
265
for control cabinets with
at least 300 mm of
depth
HCS03.1E-W0070 125 125 440
HCS03.1E-W0100 225 225 440
HCS03.1E-W0150 225 225 440
HCS03.1E-W0210 350 350 440
322
for control cabinets with
at least 400 mm of
depth
1) incl. minimum distance between the components
2) device body without mounting flange on top and bottom, as well as
minimum distances for ventilation and installation
3) incl. touch guard, connector housing, bending radius of fiber optic
cable, control panel "C"
Fig. 6-1: Mounting dimensions