Operating instructions

5-18 Electrical Data Rexroth IndraDrive
DOK-INDRV*-FU*********-IB01-EN-P
Braking Resistors for HCS03.1E-W0070
HLR01.1N-xxxx-xxxxx-A-007-
NNNN
-01K6-N18R0 -03K5-N19R0 -04K5-N18R0 -06K5-N18R0 -10K0-N18R0
continuous power kW 1,6 3,5 4,5 6,5 10
resistance value in
operating status
20,0 21,3 20,2 20,2 20,2
type A5 B1 B2 B2 B3
Energy absorption at peak power, duty cycle t = x sec and load cycle T = 120 sec
energy absorption at peak
power
kWs 109 252 432 686 1080
peak power kW 34 31 33 33 33
t sec 3,3 8 13 21 32
duty cycle ED % 2,7 6,7 11 17 27
Braking power at x % ED and a load cycle T = 120 sec
braking power kW 15 14 14 14 15
t sec7,218304872
ED % 6 15 25 40 60
Connection cross section
mm² 2,5 4 6 10 10
AWG 14 12 10 8 8
Fig. 5-29: Technical data for braking resistors at HCS03.1E-W0070