Operating instructions
Rexroth IndraDrive Electrical Data 5-17
DOK-INDRV*-FU*********-IB01-EN-P
Mains Choke HNL01.1E-****-S (Current-Compensated)
HNL01.1 … -A-480-NNNN
Unit
E-5700-S0051
E-2800-S0125
E-3400-S0202
R-4200-S0026
R-6300-S0065
R-3000-S0094
Weight kg 11 26 30 12 14 24
Inductance L
N
mH 3 x 5,7 3 x 2,8 3 x 3,4 3 x 4,2 3 x 6,3 3 x 3,0
Nominal current A 51 125 202 26 65 94
Peak current
1)
A 77 188 303 65 163 235
Total leakage current at power terminal A < 2 < 2,2 < 2,2 < 2 < 2 < 2
Allowed power dissipation at nominal current and
maximum leakage current
W 83 179 320 80 138 142
Input supply voltage 3 x AC 380…480V ±10%, 50/60Hz ±2%
Minimum inductance L
min
0,8*L
N
at I
max
Protection category IP20
1) duration: 300 ms ;
cycle duration:
for feeding units: 0,67 s;
for regenerating units: 1,42 s;
base load: 60%
Fig. 5-27: Data HNL…S
Braking Resistor HLR
HLR01.1N-xxxx-Nxxxx-A-007-NNNN
Designation Symbol Unit 0300-N17R5 0470-N11R7 0780-N07R0 1K08-N05R0
nominal braking resistance
R
DC_Bleeder
Ohm 17,5 11,7 7,0 5,0
braking resistor continuous
power, at Ta < 40 °C
P
BD
kW 0,30 0,47 0,78 1,08
resistance value at P
BD
20,5 13,7 8,2 5,8
braking resistor peak power
at U
DC
= 850 V
P
BS
kW 35 52 88 124
max. regenerative power that
can be absorbed
W
R_max
kWs 37 56 93 130
max. allowed duty cycle
ts 1 1 1 1
min. allowed cycle time
t s 120 120 120 120
time constant
s 780 780 780 780
weight
mkg 3 4,5 5,5 8
connection cross section
mm² 10 25 25 50
AWG 8 3 3 1/0
Fig. 5-28: Data