Operating instructions
4-6 Identification, Transport, Storage, Installation Conditions Rexroth IndraDrive
DOK-INDRV*-FU*********-IB01-EN-P
4.2 Transport and Storage
Transport of the Devices
Conditions
temperature -25…70 °C
relative humidity 5…95%;
climatic category 2K3
absolute humidity 1…60 g/m
3
climatic category 2K3
moisture condensation not allowed
icing not allowed
shock test out of operation according
to EN 60068-2-27
half sine in 3 axes: 10g / 11ms
Fig. 4-12: Conditions for transport
Storage of the Devices
Conditions
temperature -25…55 °C
relative humidity 5…95%;
climatic category 1K3
absolute humidity 1…29 g/m
3
climatic category 1K3
moisture condensation not allowed
icing not allowed
Fig. 4-13: Conditions for storage
Some devices contain electrolytic capacitors which may deteriorate during
storage.
Note: When storing these devices for a longer period of time,
operate them once a year for at least 1 hour with power ON:
• devices HCS with mains voltage U
LN
Extended Storage