Operating instructions

Rexroth IndraDrive Diagnostic and Service Functions 8-27
DOK-INDRV*-FU*********-IB01-EN-P
Note: Only one firmware file may be stored in the folder "Firmware"
on the MMC. With several firmware files, the message
"MMC not correct" appears on the display of the drive after
booting.
5. Remove MMC from MMC reader after writing process has been
completed.
Variant 1: Release Update with MMC
Carrying out the firmware release update with MMC makes sense when
the controller has not been equipped with a BASIC single-axis control
section.
The optional MultiMediaCard (MMC) allows transmitting drive firmware to
the drive controller in a quick and uncomplicated way.
Note: As the MMC is a storage medium that can be written in a
simple way (e.g. via PC), it is recommended that you check
the MMC content before downloading the firmware. You have
to make sure that the MMC really contains the appropriate
firmware type.
An MMC with the current release of the required firmware can be ordered
from one of our sales and service facilities.
Carrying out the firmware release update with MMC requires the following
steps:
1. Load firmware
Switch drive off.
Plug MMC with new firmware into corresponding slot at controller.
Restart drive with MMC plugged.
After drive has been booted, the following message appears:
"Firmware update?"
Acknowledge this message by pressing "Enter" key of control panel.
By doing this, firmware is loaded from plugged MMC to controller.
If drive before firmware replacement was operated without MMC
plugged, the following message appears:
"Load new param.?"
Switch drive off, remove MMC and restart drive.
2. Put machine into ready-for-operation status
Put machine into ready-for-operation status again according to
machine manufacturer's instructions.
Check functions of drive.
Selection Criterion
Firmware Update with MMC