Operating instructions
Rexroth IndraDrive Commissioning and Parameterization 7-111
DOK-INDRV*-FU*********-IB01-EN-P
master
oper. mode 2
oper. mode 1
DF000090v01_en.fh7
open-loop drive control
cmd. value adjustment
(depending on oper. mode)
drive controller
open-loop
motor control
(U/f)
- without encoder -
limitation
torque/current
Fig. 7-50: Principle of drive control in open-loop operation
The velocity control has the following features:
• fine interpolation of the velocity command value (can be switched off)
• monitoring of the velocity control loop (can be switched off via
P-0-0556, bit 1)
• filtering of actual velocity value to be parameterized
• additive velocity command value (S-0-0037)
• display of resulting command value (in P-0-0048)
• monitoring and limitation of the maximum stator frequency change
that results from the command velocity change
• stall protection loop (PI loop that can be optionally activated to
prevent breakdown of the machine when the torque limits are attained)
• slip compensation (feedforward of estimated slip of the machine by
means of rotor time constant and slip compensation factor)
• calculation of output voltage by means of a U/f characteristic based
on motor model data
• subsequent trimming of magnetization via premagnetization factor
(linear or square characteristic to be selected)
• IxR boost (adjustable load-dependent feedforward of the output
voltage due to the voltage drop on the motor winding resistance)
• oscillation damping (adjustable load-dependent feedforward to
prevent velocity oscillations in the partial load and idling ranges)
• current limitation loop to protect the output stage
• velocity search mode of a coasting machine after switching drive
enable on (can be set for one or both rotational directions)
Profibus Interface
Drive controllers of the IndraDrive range have a master communication
module with PROFIBUS interface. Via this module it is possible to
exchange real-time data with a PROFIBUS-DP master.
Using the master communication "PROFIBUS-DP" requires the following
control section design:
• single-axis BASIC PROFIBUS (not configurable) (CSB01.1N-PB)
In addition it is possible to use the following configurable control sections
if they have been designed with the optional module PB:
• single-axis BASIC UNIVERSAL (CSB01.1C)
• single-axis ADVANCED (CSH01.1C)
Features
Overview