Operating instructions

7-102 Commissioning and Parameterization Rexroth IndraDrive
DOK-INDRV*-FU*********-IB01-EN-P
Note: "Slip" is the difference of the rotational frequency of the electric
rotary field in the stator divided by the number of pole pairs of
the motor and the mechanical rotational frequency of the rotor.
The value for P-0-4043 is motor-specific and for asynchronous Rexroth
motors is made available via the commissioning software (e.g.
IndraWorks) or via the Intranet output of the manufacturer-side data base
DriveBase!
P-0-4045, Maximum possible continuous current
Input min/max: Default value: Unit:
MPB: --- / --- --- A eff
This parameter indicates how much current the controller can
continuously provide in the present load situation. At the same time, this
current is the current to which the continuous current limitation would
reduce, if the load situation would continue.
See also Functional Description "Current Limitation"
P-0-4046, Effective peak current
Input min/max: Default value: Unit:
MPB: --- / --- --- A eff
This parameter displays the maximum current that the controller can
temporarily supply to the motor in the active load condition. This is the
rms value of the total current, i.e. torque-generating and magnetic-field-
generating components are contained!
See also Functional Description "Current Limitation"
P-0-4065, Non-volatile memory active
Input min/max: Default value: Unit:
MPB: --- / --- 2 --
This parameter contains information on the active, non-volatile memory.
The parameter values and, in the case of control voltage failure, the retain
data are stored in the active memory.
Meaning of the value:
1: MultiMediaCard (MMC) is the active, non-volatile memory
2: internal, non-volatile memory is active
See also Functional Description "Parameters, Basics"
P-0-4068, Field bus: control word IO
Input min/max: Default value: Unit:
MPB: --- / --- 0 --
Function
Function
Function