P-0-0815, Nominal mains voltage crest value
Input min/max: Default value: Unit:
MPB: --- / --- --- V
This parameter for HCS converters displays the mains voltage crest value
that was measured when the mains voltage was switched in the first time.
From this value the standard value for the undervoltage threshold
(P-0-0114), the standard minimum value of the mains voltage crest value
(P-0-0810) and the standard switch-on threshold of a braking resistor
(P-0-0858) are derived.
P-0-0819, Energy counter
Input min/max: Default value: Unit:
MPB:-20000000,00 / 20000000,00 0,00 kWh
This parameter displays the energy which was supplied to the drive. The
energy is determined by means of the operating time as the sum of the
effective power.
P-0-0833, Braking resistor threshold
Input min/max: Default value: Unit:
MPB: --- / --- --- V
The braking resistor is only switched on via the firmware if this is required
for braking. This means that it is switched on whenever the DC bus
voltage is higher than the voltage threshold P-0-0833, Braking resistor
threshold.
P-0-0844, Braking resistor load
Input min/max: Default value: Unit:
MPB: --- / --- --- %
This parameter indicates the thermal energy in percent, in relation to its
maximum allowed energy content, currently stored in the braking resistor.
P-0-0858, Data of external braking resistor
Input min/max: Default value: Unit:
MPB: --- / --- --- --
For HCS02/HCS03 converters the type data of an externally connected
braking resistor are entered in this list parameter.
Note: For HCS03 devices there is only an optional external braking
resistor available!
See also Functional Description "Power Supply"