P-0-0528, Flux control loop proportional gain
Input min/max: Default value: Unit:
MPB: 0,00 / 100,00 1,00 --
For asynchronous motors, the gain of the flux loop is entered in this
parameter.
See also Functional Description "Field-Oriented Closed-Loop Current
Control"
P-0-0529, Scaling of stall current limit
Input min/max: Default value: Unit:
MPB: 10 / 150 100 %
The stall current limit is the limit for the torque-generating current of
asynchronous motors.
See also Functional Description "Field-Oriented Closed-Loop Current
Control"
P-0-0530, Slip increase
Input min/max: Default value: Unit:
MPB: 1,00 / 2,00 1,50 1/100K
This parameter is only used for asynchronous motors. In the
asynchronous motor the rotor resistance and therefore the rotor time
constant change as the temperature changes.
See also Functional Description "Field-Oriented Closed-Loop Current
Control"
P-0-0532, Premagnetization factor
Input min/max: Default value: Unit:
MPB: var. / var. 100 %
With this parameter it is possible to reduce the magnetizing current of an
asynchronous motor and therefore the rotor flux. The factor is referring to
P-0-4004, Magnetizing current.
See also Functional Description "Motor, Mechanical Axis System,
Measuring Systems"
P-0-0533, Voltage loop proportional gain
Input min/max: Default value: Unit:
MPB: 0,000 / 4294967,295 0,500 A/V