Operating instructions

7-70 Commissioning and Parameterization Rexroth IndraDrive
DOK-INDRV*-FU*********-IB01-EN-P
Note: Only such IDNs can be entered in P-0-0213 that are contained
in P-0-0212, Analog input, list of assignable parameters.
See also Functional Description "Analog Interface"
See also Functional Description "Analog Inputs"
P-0-0237, Analog input, assignment B, scaling per 10V
full scale
Input min/max: Default value: Unit:
MPB: --- / --- 0 --
By means of this parameter the analog input for assignment B (range of
values per 10 V) is scaled.
Unit, decimal places and data type are determined by the parameter
assigned in P-0-0236, Analog input, assignment B, target parameter.
See also Functional Description "Analog Interface"
See also Functional Description "Analog Inputs"
P-0-0238, Analog input, assignment B, signal value at 0V
Input min/max: Default value: Unit:
MPB: --- / --- 0 --
In this parameter the reference of the analog input for assignment B
(value with a voltage of 0 V at the analog input) is defined. This allows
compensating a possible offset of the voltage at the analog input.
Unit, decimal places and data type are determined by the parameter
assigned in P-0-0236, Analog input, assignment B, target parameter.
See also Functional Description "Analog Interface"
See also Functional Description "Analog Inputs"
P-0-0239, Analog input, assignment B, dead zone
Input min/max: Default value: Unit:
MPB: 0,000 / 10,000 0,000 V
By means of this parameter it is possible to define a range of values for
the analog input voltage (assignment B). The controller interprets this
range of values as voltage value 0 V ("dead zone").
P-0-0300, Digital I/Os, assignment list
Input min/max: Default value: Unit:
MPB: --- / --- --- --
Via parameter P-0-0300 drive signals are assigned to the digital
inputs/outputs of the control section by configuring the corresponding IDN
in the list parameter.
Function
Function
Function
Function