Operating instructions

7-58 Commissioning and Parameterization Rexroth IndraDrive
DOK-INDRV*-FU*********-IB01-EN-P
Fig. 7-41: P-0-0101, Configuration for starting lockout selector
P-0-0102, Oper. hours power section at last activat. of
start. lockout
Input min/max: Default value: Unit:
MPB: --- / --- 0,0 s
Parameter P-0-0102, Oper. hours power section at last activat. of
start. lockout displays the operating hours of the power section since the
last time the starting lockout function was deselected.
P-0-0105, Time stamp for list of diagnostic message
numbers
Input min/max: Default value: Unit:
MPB: --- / --- --- s
This parameter contains a list of the points of time at which the diagnostic
drive message was changed. At each change of S-0-0390, Diagnostic
message number the respective point of time (value from P-0-0190,
Operating hours control section) is recorded. The last point of time at
which the diagnostic message was changed is entered in the first line of
the list, all entries already existing are moved down by one line. The list is
full after 50 entries, each other entry causes the oldest value to get lost.
The list from P-0-0105 corresponds with S-0-0375, List of diagnostic
numbers. These parameters in the same line contain the diagnostic
message number corresponding to the respective point of time.
Note: The numbers of the diagnostic error messages and the
respective points of time of the error events are only accepted
in S-0-0375 and P-0-0105 by clearing the error message!
P-0-0109, Torque/force peak limit
Input min/max: Default value: Unit:
MPB: 400,0 S-0-0086
Torque/force limit value that acts on the sum of all torque/force command
values:
command values from the acceleration feedforwards (S-0-0348,
P-0-1126)
command values from the velocity controller (P-0-0049)
See also Functional Description "Torque/Force Limitation"
P-0-0114, Undervoltage threshold
Input min/max: Default value: Unit:
MPB: 0 / 500 0 V
Function
Function
Function