Enter Motor Data:
At the beginning of parameterization you must enter the motor data (see
type plate of motor).
Data field in which you can make inputs is highlighted in black.
Fig. 7-19: Enter motor data (example)
List
element
Characteristic
value of motor Unit Definition
0 rated current A
eff
rms value of the electric current in
the motor feed wire (motor phase) at
rated load
1 rated voltage V
eff
rms value of the phase-to-phase
voltage between the motor terminal
pins at rated load
2 rated frequency Hz frequency of the feeding, sinusoidal
electric voltage
3 rated speed 1/min speed of motor output shaft at rated
load
4 power factor cos 1 power factor at rated load
5 rated power kW mechanical power that can be
continuously delivered at rated load
Fig. 7-20: List elements P-0-4032
• Data field in which you can make inputs is highlighted in black.
• With key
or you can select a specific data field.
• With keys
, , Prog
+
, Mon enter desired value:
, : move cursor to the left or to the right
Prog
+
, Mon: change setting
• With Enter key confirm entered value.
Next data field is automatically activated.
• When you have made all inputs:
Press Esc key.