Rexroth IndraDrive Mounting and Installation 6-81
DOK-INDRV*-FU*********-IB01-EN-P
According to required power supply cable and motor cable routing, it is
possible to mount shielding plate for shield connection in different
positions.
3. Fix shield of power supply cable and motor cable to shielding plate
with a clip.
Fig. 6-105: Shielding plate HAS02.1-008-NNN-NN at the bottom of the drive
controller HCS03.1E-W0210
Note: Adapt the size of the clip to the power supply cable and motor
cable cross sections.
Shield Connection of Motor Cable via Mains Filter
For shield connection of the motor cable at the drive controller via the
mains filter, a special shielding plate is available:
Note: Using the shielding plate guarantees optimum shield contact
of the motor cable. You should therefore always use the
shielding plate, where possible.
The shielding plate is only available as an option.
1. Hang up shielding plate at bottom of mains filter at threaded bolts and
fasten with supplied nuts.
2. Screw support to shielding plate.
Clips can be mounted depending on motor cable cross section.
Shield Connection of Motor
Cable HAS02.1-006-NNN-NN with
Mains Filter Mounted: