Operating instructions

6-54 Mounting and Installation Rexroth IndraDrive
DOK-INDRV*-FU*********-IB01-EN-P
The control voltage supply is routed to the connection X13 from above
(see following figure).
1: lines to control voltage supply
Fig. 6-77: Control voltage supply at X13
Optional Control Voltage (HCS03)
Control voltage is supplied by an external 24V power supply unit.
Note: Technical data of control voltage: see section "Electrical Data"
The control voltage supply is connected via contact bars and screws (M6)
at the front of the drive controller. Depending on the width of the drive
controllers, there are contact bars of different lengths.
6 Nm
The following figures show the correct control voltage connection for
stacked drive controllers. The illustrated way of connection ensures that
the touch guard can be correctly mounted and the required clearances
and creepage distances can be complied with.
The cables have to be twisted. Observe the notes in chapter "Arranging
the Components in the Control Cabinet", section "Installing the 24V
Supply".
Design
Tightening Torque
Multiple-Line Arrangement