Rexroth IndraDrive Mounting and Installation 6-51
DOK-INDRV*-FU*********-IB01-EN-P
HCS03.1E-
Type No. of
poles
Type of design
W0070 Connector 2 Screw connection
W0100..0210 Screw terminal
block
2 Screw connection
Fig. 6-66: Design
Identification of the individual connections::
Identification Significance
1 Phase 1
2 Phase 2
Fig. 6-67: Identification of the individual connections
HCS02.1E- Cross section
single-wire
[mm²]
Cross section
multi-wire
[mm²]
Cross section
in AWG
W0054, W0070 0,5-10 0,5-10 20-8
Fig. 6-68: Connection cross sections
HCS03.1E- Cross section
in [mm²]
Cross section
in AWG
W0070 16 6
W0100, W0150 25 4
W0210 50 0
Fig. 6-69: Connection cross sections
HCS02.1E- Tightening torque [Nm]
W0054, W0070 1,2 – 1,5
Fig. 6-70: Tightening torque
HCS03.1E- Tightening torque [Nm]
W0070 1,5
W0100, W0150 2
W0210 8
Fig. 6-71: Tightening torque
CAUTION
Damage to the drive controller!
You have to provide strain relief for the connection
cable in the control cabinet or use the optionally
available connection accessory (shielding plate;
HAS02.1).
Note: With twisted or shielded cable, the maximum cable length for
the braking resistor is 5 m.
Connection Cross Section
Tightening Torque